B U T T O N P R O G R A M M I N G E X A M P L E S
Sequential Programming
a. Right-click in the Device column then select MOTOR
b. Right-click in the Command column then select
SEQUENCE
NOTE: Sequence cycles Up, Stop, and Down commands. The Stop command
will expire after 60 seconds and default to the next movement command after
the button is pressed.
Single Action Programming
a. Right-click in the Device column then select
MOTOR
b. Right-click in the Command column then select
the required action to perform
NOTE: To send a group to a percentage, select GOTO in the Command
dropdown then enter a percentage in the Value field. Only enter the
number value (0-100).
Create Group Raise / Lower
a. Right-click in the Device column then select MOTOR
b. Right-click in the Command column then select OPEN
c. Click the Copy button to create an identical map below
d. Edit the Lutron ID and change the Command column from OPEN to CLOSE
Group Control
a. Right-click in the Device column then select KEY;
repeat this step for each group button and be sure
to change the Button ID each time
b. Enter SDN Group Address; repeat this step for
each group button
Momentary Button Press
*Requires both a Multi-tap and a Release function added to the Lutron table.
For Hold / Release Command
a. Right-click in the Lutron ID column, set Action to MULTI-TAP then set the Button
b. Right-click in the Device column then select MOTOR
c. Right-click in the Command column then select a movement
d. Right-click in the Lutron ID column then set Action to RELEASE (set the same Button from previous steps)
e. Right-click in the Device column then select MOTOR
f. Right-click in the Command column then select STOP
15 of 16