35
ADJUSTING THE MINIMUM BURNER SETTINGS
Adjusting the cooktop burner minimums
The flame has been regulated by the factory. When the injectors have been
replaced or there are special mains pressure conditions, it may be necessary
to regulate the minimum flame again. Check whether the flame spreads to
all burner ports when the burner is lit with the gas tap set to the minimum
position.
•
If some ports do not light, increase the minimum gas rate setting.
•
Check whether the burner remains lit even when the gas tap is turned
quickly from the maximum to the minimum position.
•
If the burner does not remain lit, increase the minimum gas rate setting.
To regulate the flame follow these instructions:
Auxiliary, Rapid, Semi-Rapid, Triple-ring Wok Burners
•
Light the burner.
•
Set the gas valve to L0 (minimum rate).
•
Remove the knob.
•
With a thin screwdriver, turn the regulation screw inside the tap rod until
adjustment is correct.
Regulation screw (Auxiliary, Rapid, Semi-Rapid, Triple-ring and Single Wok burners)
Lubrication of the gas valves
•
If a gas valve becomes stiff, it is necessary to dismantle it carefully and clean it with
petroleum spirit.
•
Specialist high temperature resistant grease should be used to lubricate the valve
before replacing.
•
This must be carried out by an authorised person or service agent. Please call our After Sales
Service team on 1300 11 HELP (4357) to arrange one.
[Need updated drawing from Arda that is relevant to the Arda burners]
ADJUSTING THE MINIMUM BURNER SETTINGS
Adjusting the cooktop burner minimums
The flame has been regulated by the factory. When the injectors have been replaced or there
are special mains pressure conditions, it may be necessary to regulate the minimum flame
again.
Check whether the flame spreads to all burner ports when the burner is lit with the gas tap
set to the minimum position.
-
If some ports do not light, increase the minimum gas rate setting.
-
Check whether the burner remains lit even when the
gas tap is turned quickly from the maximum to the
minimum position.
-
If the burner does not remain lit, increase the minimum
gas rate setting.
To regulate the flame follow these instructions:
Page 31
Regulation Screw