User Manual UM0025_ASW3000-6000H-S2_EN_V02_0722 57
Waiting:
when the inverter does not meet the requirements of
each mode
(
When the initial voltage of the strings is greater than
the minimum DC input voltage but lower than the start-up DC
input voltage, battery voltage lower than the start-up battery input
voltage or BMS communication not connect) the inverter is
waiting for sufficient DC input voltage and cannot feed power into
the grid.
Checking:
When the inverter meets the start-up conditions of
each mode. the inverter will check feeding conditions at once. If
there is anything wrong during checking, the inverter will switch
to the “Fault” mode.
Normal:
After checki
ng, the inverter will switch to “Normal” state
and feed power into the grid.
During periods of low radiation, the inverter may continuously
start up and shut down. This is due to insufficient power
generated by the PV array.
If this fault occurs often, please call service.
If the inverter is in "Fault" mode, refer to Section 11
"
Troubleshooting
".