User Manual UM0025_ASW3000-6000H-S2_EN_V02_0722 53
④
Check the PV array’s insulation to ground with a multimeter:
make sure that the insulation resistance to ground is greater
than 1 MOhm.
⑤
Check the grid voltage: check that the grid voltage at the point
of connection of the inverter complies with the permitted
value.
⑥
Check the battery voltage: check that the battery voltage at
the point of connection of the inverter complies with the
permitted value.
⑦
Check the polarity of the battery voltage: make sure the
battery voltage has the correct polarity.
⑧
Check the battery communication connection : Check the
battery BMS communication cable connection is normal.
Danger to life due to the presence of AC Voltage
Touching the live conductors can lead to lethal electric
shocks.
• Only touch the insulation of the AC cables.
• Wear personal protective equipment such as insulating
gloves.