Technical
Service
as
at:
08/07/2009
phone: +49 30 81879 0 fax: +49 30 81879 9999
www.solon.com
34
SOLON P220/6+ (Horizontal Assembly / Pitched Roof or Slanted Roof)
Allowable
snow
loads
on
the
ground
s
kallow
in
kN/m²
according
to
DIN
1055-5
(Version
07.2005)
depending
on
the
pitch
of
the
roof
and
the
module
and
the
speed
pressure
q
in
kN/m²
Only
optimum
support
and
attachment
area
allowed
Speed pressure q = 1.05 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.32
1.33
1.34
1.35
1.37
1.38
1.38
1.39
1.39
1.40
20°
1.40
1.41
1.42
1.43
1.44
1.45
1.46
1.48
1.50
1.51
30°
1.53
1.60
1.68
1.77
1.87
1.97
2.09
2.22
2.37
2.53
40°
2.72
2.92
3.15
3.42
3.72
4.08
4.52
5.03
5.65
6.40
50°
7.29
8.44
9.91
11.79
14.40
18.14
23.67
33.29
52.94 109.76
60°
No calculative consideration of the snow load, usable in all snow load zones.
Speed pressure q = 1.15 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.31
1.32
1.33
1.34
1.35
1.36
1.36
1.37
1.37
1.38
20°
1.38
1.39
1.39
1.40
1.41
1.42
1.43
1.45
1.46
1.47
30°
1.49
1.56
1.64
1.72
1.81
1.91
2.02
2.15
2.28
2.44
40°
2.61
2.80
3.03
3.28
3.56
3.90
4.32
4.80
5.39
6.10
50°
6.95
8.04
9.43
11.21
13.68
17.23
22.46
31.57
50.17 103.95
60°
No calculative consideration of the snow load, usable in all snow load zones.
Speed pressure q = 1.25 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.29
1.30
1.31
1.32
1.33
1.35
1.35
1.35
1.35
1.35
20°
1.36
1.36
1.37
1.37
1.38
1.39
1.40
1.41
1.42
1.44
30°
1.45
1.52
1.59
1.67
1.75
1.85
1.95
2.07
2.20
2.35
40°
2.51
2.69
2.90
3.14
3.40
3.72
4.12
4.57
5.13
5.80
50°
6.60
7.63
8.95
10.63
12.97
16.32
21.25
29.85
47.41
98.14
60°
No calculative consideration of the snow load, usable in all snow load zones.
Speed pressure q = 1.30 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.28
1.29
1.30
1.31
1.33
1.34
1.34
1.34
1.34
1.34
20°
1.35
1.35
1.36
1.36
1.37
1.38
1.38
1.39
1.41
1.42
30°
1.43
1.49
1.56
1.64
1.73
1.82
1.92
2.03
2.16
2.30
40°
2.46
2.63
2.84
3.07
3.32
3.63
4.01
4.46
5.00
5.65
50°
6.43
7.43
8.71
10.34
12.61
15.86
20.65
28.99
46.02
95.23
60°
No calculative consideration of the snow load, usable in all snow load zones.
Speed pressure q = 1.40 kN/m²
β
0°
1°
2°
3°
4°
5°
6°
7°
8°
9°
10°
1.27
1.28
1.29
1.30
1.31
1.32
1.32
1.32
1.32
1.32
20°
1.32
1.33
1.33
1.33
1.34
1.35
1.35
1.36
1.37
1.38
30°
1.39
1.45
1.52
1.59
1.67
1.75
1.85
1.96
2.07
2.21
40°
2.36
2.52
2.71
2.92
3.17
3.45
3.81
4.23
4.74
5.35
50°
6.09
7.03
8.23
9.76
11.89
14.94
19.44
27.27
43.25
89.42
60°
No calculative consideration of the snow load, usable in all snow load zones.
SOLON M230/6+ is structurally identical with SOLON P220/6+.