8
Figure 3: Horizontal insertion profiles
Figure 4: Vertical girder profiles
Standardmodule
L
[mm]
B
[mm]
a
optimal
[mm]
M
W
[mm]
SOLON Blue 230/07
1.640
1.000
980
150
SOLON Black 230/07 (01, 02)
1.640
1.000
980
150
SOLON Blue 220/03 (01, 07)
1.640
1.000
980
150
SOLON Black 280/10,
1.580
1.070
940
145
SOLON Black 300/10
1.580
1.070
940
145
SOLON P220/6+/07
1.640
1.000
980
150
SOLON M230/6+/07
1.640
1.000
980
150
SOLON M230/6+/01
1.640
1.000
980
150
SOLON P220/6+
1.660
990
1.000
150
SOLON M230/6+
1.660
990
1.000
150
SOLON P180/6+
1.660
830
1.000
200
SOLON P130/6+
1.500
680
900
300
2.
Assembly of Modules on Flat Roofs (installation on supports, assembly non-parallel to
the roof):
When
installing
modules
on
flat
roofs,
it
is
recommended
to
use
a
substructure
which
provides
an
optimal
support
in
the
area
of
the
slip
protection
boreholes
without
special
efforts.
Depending
on
the
type
of
assembly
(horizontal
or
vertical),
the
frame
of
the
module
must
always
be
attached
(without
deformation)
to
the
rails
of
the
substructure
(girder
profiles)
at
four
points
in
one
plane
in
the
respectively
specified
installation
area
"M
w
"
or
"M
s
"
.
Otherwise
the
details
from
"Assembly
of
Modules
on
Pitched
or
Slanted
Roofs"
(Item
1.)
apply.
3. General Notes
When
using
commercially
available
assembly
systems,
minimal
stress
for
the
modules
is
achieved
by
optimal
positioning
of
the
mounting
rails
as
well
as
support
and
attachment
in
the
area
of
the
boreholes
(distance
a
optimal
)!
At
this,
it
is
always
assumed
that
the
commercially
available
assembly
systems
that
are
used,
which
can
not
be
considered
in
the
assembly
instructions,
correspond
to
the
latest
state
of
technology.
The
dimensioning
of
the
substructure
must
be
realized
in
a
way
that
allows
deflection
of
l/200,
but
not
exceeding
a
maximum
of
15
mm.
Make
sure
that
the
roof
construction
itself
is
suitable!
Attachment
directly
on
the
frame
(using
the
slip
protection
boreholes
of
the
long
spar)
with
high-strength
bolts
M6
made
of
stainless
steel
without
pre-stressing
is
allowed
if
washers
with
a
diameter
of
at
least
14
mm
are
used
and
the
connection
is
carried
out
without
stress.
Table 3: Assembly area "M
W
" – horizontal assembly
Attention!
When
installing
modules
horizontally,
approval
is
only
given
for
the
optimal
attachment
area
"
M
w
",
irregardless
of
the
assembly
system.
The
frame
of
the
module
must
be
connected
to
the
rails
of
the
substructure
(girder
profiles)
at
four
points
in
the
area
"
M
w
".