- 13 -
3.
Configuring IP Address and Environmental
Variables
3.1.
IP Address and Environmental Variables
For TCP/IP communication, you must set IP address related items. In addition, you have
to set serial port related items (baud-rate, data bit length, parity bit, flow control, etc) to
EZL-200L.
You can set the IP address and the serial port related items by using ezConfig, the
supplied configuration utility which allows you to configure your EZL-200L over the
network, or by using AT commands in ATC mode.
Item
Description
Local IP
Address
IP address of EZL-200L
Subnet Mask
Subnet mask
Gateway IP
Address
IP address of gateway
Local Port
Port number for waiting to be
connected in Server mode
Port number for waiting UDP data
Peer IP Address
IP address to connect in Client mode
IP address to send data in UDP mode
Peer Port
Port number to connect in Client mode
Port number to send data in UDP mode
IP Address-related
Items
Permitted IP
Address
Permitted IP address in server mode.
Baudrate
Serial Port Speed(bps)
Data bits
Data bit length
Parity
Parity
Stop bit
Stop bit
Serial Port
Flow Control
Flow control
Communication Mode
ezTCP Mode
Communication Mode