M
Page 3
3
of 36
SOLIS Ltd
SOLIS-House
CH-8152 Glattbrugg
SOLIS MASTER TOP
8_DWA fixt water connection_M_e
29.08.05 B.K.
30.08.05
Prior to installation please check:
•
whether there is a mains power supply point near the appliance
•
whether there is a drinking water tap with water faucet near the appliance
•
whether a water softening unit has already been installed, yes/no
Depending on the hardness of the water, an appropriate filter must be installed. If there is
no water softening unit, a suitable filter system is available from SOLIS Ltd.
1. Installation
a) Place the appliance on a flat, solid base.
b) Check that the voltage indicated on the rating plate is the same as the mains electricity
supply voltage. (See original SOLIS MASTER TOP users manual, page 7).
c) The water supply connection point is located at the rear side of the appliance at the
bottom left comer. The appropriate connecting elements are included in the
connection set. Wind teflon tape around the threaded joints or use the sealing agent
included in the set to ensure that they are seal. (SOLIS AG cannot accept any liability
for water damage caused by incorrect Installation).
d) The pressure-relief valve is to be installed right after the water faucet, as shown in
above plan. To ensure optimum functioning of the appliance, the pressure-relief valve
has already been correctly Set at our factory. Do not alter this setting.
e) After connecting the pressure hose to the water supply, open the water faucet briefly
before connecting the hose to the machine so as to clean the hose and the connecting
elements. This ensures that no dirt gets into the SOLIS MASTER TOP.
f) Remove the plastic cover over the appliance connection point. Connect the pressure
hose to the appliance with inserted seal.
g) Connect the plug to the mains power supply. The SOLIS MASTER TOP is now ready
to operate. (Please refer to Original user‘s manual.)
2. Starting up the SOLIS MASTER TOP:
The appliance was drained after thorough testing before leaving the factory. Proceed as
per the Original user‘s manual, page 8, point 3.3 etc.
IMPORTANT:
If the insufficient water control indicator comes on during operation (see original user‘s
manual, page 5, “Indicator explanations”), this may mean that:
The water filter in the pressure hose is dirty.
Shut off water faucet. Remove water filter in pressure hose and clean or decalcify if
necessary. Reinsert water filter and reconnect pressure hose. Open water faucet.
NOTE: Do not operate the SOLIS MASTER TOP without a water filter.