12.03.01 B.K
30.08.05
Special programming functions and errror messages,
SOLIS MASTER TOP
The standard software of the SOLIS MASTER TOP integrates various special programming
functions. Please proceed as follows:
•
Switch machine to stand-by
•
Press and hold the selection switch mentioned below and switch on the machine with
the operating switch (1).
•
Program value with the quantity selection switch, if required (5).
•
Register the new program data with the programming switch (7).
Refere to page 4 of the operating manual.
Stand-by mode:
Key combinationen
Programing function
3
reset counter for cleaning
7 defaults
7 + 8
Factory Preset
description:
defaults: remarks:
OFF
time
5
5h
pre infusion
ON
espresso, coffee
rinsing at ON
ON
coffee volume Espresso 4
coffee volume Coffee
4
coffee volume Pot
4
temperature
4
steam
boiler
ON
2
grinder current
2
replacement PCB
x
new
machines
On factory preset, descaling indication and grinder current remains
the same.
7 + 6
Descaling indication
1- 6 LED flashes
1 =
625 coffee / ca. 100 Liter
> 14 dH
> 250 ppm
2 = 1325 coffee / ca. 200 Liter
13 –14 dH 232 – 250 ppm
3 = 2325 coffee / ca. 350 Liter
10 –12 dH 178 – 214 ppm
4 = 4500 coffee / ca. 600 Liter
7 – 9 dH 125 – 160 ppm
5 = 5500 coffee / ca. 750 Liter
5 – 7 dH 89 – 125 ppm
6 = (no indication)
7 + 2
Grinder current adjustment
1- 6 LED flashes
program the value indicated on the grinder label