Storing the appliance for extended periods
Clean the appliance as described earlier and allow to dry thoroughly. Preferably store the appliance in its
original box, in a dry place away from high temperatures.
TROUBLESHOOTING
Problem
Possible cause
What to do
Unit does not operate
Power plug not plugged in
Plug in power plug into mains socket
No water in the tank
Fill tank with water
(Empty indicator is on)
No mist output
Desired humidity level lower
Increase humidity setting
than actual
Cleaning agent residues
Rinse with clear water
Weak mist output
Water temperature too low
Set mist output to maximum.
The appliance will work properly
after 10 minutes.
Mineral deposits on membrane
Clean membrane
White deposit around
Demineralisation cartridge
Replace demineralisation cartridge
the appliance
exhausted
CLEANING/MAINTENANCE
Replacement of the demineralisation cartridge
Always switch off the appliance before removing the water tank.
Do not reach inside the nebuliser space while the appliance is running!
The cartridge must be replaced every 2-3 months. If the water is very hard, it may be necessary to replace
the cartridge earlier. White dust around the appliance is a sure sign that the cartridge needs replacing. If
white residues continues to form around the appliance after a new cartridge has been inserted, please
make sure that the water you are using is untreated. If the water flows through a domestic decalcification
system before it is used in the unit, salt will precipitate around the appliance.
• Remove the water tank from the base and unscrew the water tank cap (25).
• The demineralisation cartridge is attached to the inside of the tank cap. Unscrew the cartridge from
the cap by turning it counter-clockwise (26). Important: do NOT dispose of the tank cap!
• Dispose of the old cartridge (27).
• Unpack the new cartridge (27).
• Soak the new cartridge in a bowl of water for at least 24 hours before use (28).
The granules have to absorb water to reach full performance.
• Now screw the cartridge onto the water tank cap (29). Close the tank cap securely!
Place the water tank onto the base (30).