SOLiD RocketWAVE™ SRF-L-1835 Product Manual
V1.6 - DEC 2021
© 2021 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
Page 24
⑤
If the isolation is not sufficient, change the location of
the repeater or turn it away from the donor antenna.
UL Output Upper-
limit
- Blinking green while processing the
algorithm
- Blinking red while shutting down for
30 mins.
- Solid red while fully shutting down
This alarm is raised when output
power is over +3 dB than rated output
power.
1.8GHz : 21 dBm
3.5GHz : 21 dBm
①
Access to the LMT and check output power upper-limit
is set correctly.
②
Check the isolation is sufficient.
③
If the isolation is not sufficient, change the location of
the repeater or turn it away from the donor antenna.
Shutdown for
Insufficient Isolation
- Solid red
This alarm is raised when the isolation
is not sufficient between antennas.
①
Change the location of the repeater or change the loca-
tion of the antenna.
3.5GHz TDD Sync
- Solid red
This alarm is raised when SSB fre-
quency change, SSB index change,
Low Input (RSRP), Low SINR (PSS),
or other unknown issue occurs.
①
Check cable connection status between a Donor An-
tennas.
②
Check the input signal is detected correctly using LMT
(Local GUI).
③
Check ARFCN is 643654.
④
Turn the device power off and on and check the device
operates correctly.
⑤
If not, replace the device.
PLL Unlock
- Solid red
This alarm is raised when the local fre-
quency is not generated due to PLL
abnormal operation.
①
Turn the device power off and on and check the re-
peater operates correctly.
②
If not, replace the repeater.
Digital Board Error
- Solid red
This alarm is raised when digital board
has a problem or communication error
occurs.
①
Turn the device power off and on and check the re-
peater operates correctly.
②
If not, replace the device.