If the isolation is not sufficient, change the location of 

the repeater or turn it away from the donor antenna. 

UL Output Upper-

limit 

-  Blinking green while processing the 

algorithm 

-  Blinking red while shutting down for 

30 mins. 

-  Solid red while fully shutting down 

This alarm is raised when output 

power is over +3 dB than rated output 

power. 

1.8GHz : 21 dBm 

3.5GHz : 21 dBm 

 

Access to the LMT and check output power upper-limit 

is set correctly. 

 

Check the isolation is sufficient. 

 

If the isolation is not sufficient, change the location of 

the repeater or turn it away from the donor antenna. 

Shutdown for   

Insufficient Isolation 

-  Solid red 

This alarm is raised when the isolation 

is not sufficient between antennas. 

 

Change the location of the repeater or change the loca-

tion of the antenna.   

3.5GHz TDD Sync 

-  Solid red 

This alarm is raised when SSB fre-

quency change, SSB index change, 

Low Input (RSRP), Low SINR (PSS), 

or other unknown issue occurs. 

 

Check cable connection status between a Donor An-

tennas. 

 

Check the input signal is detected correctly using LMT 

(Local GUI). 

 

Check ARFCN is 643654. 

 

Turn the device power off and on and check the device 

operates correctly. 

 

If not, replace the device. 

PLL Unlock 

-  Solid red 

This alarm is raised when the local fre-

quency is not generated due to PLL 

abnormal operation.   

 

Turn the device power off and on and check the re-

peater operates correctly. 

 

If not, replace the repeater. 

Digital Board Error 

-  Solid red 

This alarm is raised when digital board 

has a problem or communication error 

occurs. 

 

Turn the device power off and on and check the re-

peater operates correctly.   

 

If not, replace the device. 

 

Summary of Contents for RocketWAVE SRF-L-1835

Page 1: ...RocketWAVE SRF L 1835 Product Manual DEC 2021 V1 7 ...

Page 2: ...respect to such trademark Other product names mentioned in this manual are used for identification purposes only and may be trademarks or registered trademarks of their respective companies Disclaimer of Liability The contents of this document including graphics and screenshots are current as of the date of publication SOLiD reserves the right to change the contents without prior notice In no even...

Page 3: ... 7 2 1 System Overview 7 Service Frequency Bandwidth 7 In Output Power Gain 7 2 2 Functions 8 Repeater Interface 11 Package Configuration 12 Installation 13 5 1 Donor antenna installation 13 5 2 Repeater installation 13 5 3 USIM Installation 16 Software 17 6 1 LMT DT_GUI installation 17 6 2 LMT User Interface 18 6 3 Firmware Upgrade 20 Appendix 21 7 1 General specification 21 7 2 RF specification ...

Page 4: ...ons or fit any spare parts which are not sold or recommended by the manufacturer This could cause fires electric shock or other injuries Any repeater including this repeater will generate radio signals and thereby give rise to electromagnetic fields that may be hazardous to the health of any person who is extensively exposed to the signals at the immediate proximity of the repeater and the repeate...

Page 5: ...ic Discharge Immunity IEC61000 4 2 2008 Radiation Electromagnetic Immunity IEC61000 4 3 2006 A1 2007 A2 2010 FAST TRANSIENT IMMUNITY IEC61000 4 4 2004 SURGE IMMUNITY IEC61000 4 5 2005 CONDUCTED DISTURBANCES IMMUNITY IEC61000 4 6 2008 VOLTAGE DIPS INTERRUPTION VARIATIONS IEC61000 4 11 2004 The installation to comply with European EN50385 exposure compliance requirements the following Power Density ...

Page 6: ...ve 2011 65 EU Declaration of Conformity SOLiD declares that the radio equipment type Repeater is in compliance with Directive 2014 53 EU The Full text of the EU declaration is available at the following website https solid com emea resources product literature WEEE Recycling SOLiD complies with collection and recycling arrangements per the Waste Electrical and Electronic Equipment WEEE Directive a...

Page 7: ...evice complies the various standard and regulation such as CE RoHS Fireload etc The device comes with various embedded function and feature for the stable and sustainable O M The LTE modem is embedded in the device that support NMS by communicating through LTE signal System operation can be monitored by carrier NMS in NoC And through this NMS feature the device S W can be easily upgraded and fix w...

Page 8: ...the feedback signal are used If isolation value is measured Gain 7 dB at 1 8 GHz or Gain 12 dB at 3 5 GHz more than 30 seconds the repeater reports oscillation alarm and shuts down 5 seconds later And the repeater maintains its shutting down state until the power turned off and on or performs CPU reset Even though the oscillation state is maintained for more than 30 seconds the oscillation may occ...

Page 9: ...Bm 12 dBm 49 dB 49 dB 32 dBm 12 dBm 44 dB 44 dB 27 dBm 12 dBm 39 dB 39 dB 22 dBm 12 dBm 34 dB 34 dB N78 3600 MHz DL Input RSSI DL Output DL Gain UL Gain 60 dBm 12 dBm 72 dB 72 dB 54 dBm 18 dBm 72 dB 72 dB 49 dBm 18 dBm 67 dB 67 dB 44 dBm 18 dBm 62 dB 62 dB 39 dBm 18 dBm 57 dB 57 dB 34 dBm 18 dBm 52 dB 52 dB 29 dBm 18 dBm 47 dB 47 dB 24 dBm 18 dBm 42 dB 42 dB Auto Level Control ALC for UL over inpu...

Page 10: ...dware from the ALC one Shutdown for UL DL over output This function is that automatically shutting down the service band when the DL UL output of each service band is over the rated During DL Shutdown UL Shutdown is also proceed at the same time and this is vice versa The operating level is Rated output level 2dB 2dB and working algorithm is described as follows In Check state if the power level i...

Page 11: ...SOLiD RocketWAVE SRF L 1835 Product Manual V1 6 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 11 Repeater Interface ...

Page 12: ...SOLiD RocketWAVE SRF L 1835 Product Manual V1 6 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 12 Package Configuration ...

Page 13: ...the repeater Check the repeater LED indicator is in green Install the donor antenna SRF_HP1_ANT_B3N78 Choose the suitable location for the antenna and make holes to secure the bracket on the wall Assemble the antenna to the bracket on the wall Refer to the graphic below The Hole marking sticker and Wall plug in above graphic are not compulsory accessories which may not be included in the package T...

Page 14: ...duct Manual V1 6 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 14 B Install the repeater Table standing bracket SRF_BRK_Stand_DB Find suitable location to place the bracket that is included in the package ...

Page 15: ...etWAVE SRF L 1835 Product Manual V1 6 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 15 C Clearance When placing the repeater it requires the minimum space to keep distance from another ...

Page 16: ... 16 Remove four M3 screws at each corner of the bottom and split up the top cover of the enclosure The USIM tray is located at the mid right side of the enclosure Remove the USIM cover by loosening the two screws Insert a USIM card into the slot as described as below pictures To remove the USIM card push the inserted card ...

Page 17: ...e environment of the PC A Install LMT 1 Run the installation file and follow the instruction to finish the installation 2 Click DT_GUI icon on the desktop B Run LMT DT_GUI 1 When DT _GUI runs it asks to login Enter admin for initial password and click Login button 2 When the login is successful a repeater model selection popup appears When the popup appears check Auto Select If you want to select ...

Page 18: ...ual V1 6 DEC 2021 2021 SOLiD Inc All Rights Reserved Confidential Proprietary Page 18 3 Click UDP button and then click Connect button to access to the repeater No Description Repeater model name Connection status Repeater modem information ...

Page 19: ...o provides reporting on and off button Displays the information of the repeater s Plug and Play function When the repeater is connected to the upper layer NMS the IP addresses APN and certificate information appears Provides user controllable panel for the repeater installation information Setup the date installed the location of the repeater and also GPS on and off are available When the GPS is O...

Page 20: ...ng button its level controller and function on and off are available To turn on the AGC click Then the button changes to Provides the Isolation controllable panel Click to perform Isolation Recheck When the re peater measures the isolation value it appears Isolation Value and the gain value is automatically tuned Provides the LTE TDD controllable panel TDD Sync alarm sync mode and time setting are...

Page 21: ... 16 92 W Cooling Passive Port Interface Antenna port 1 port for donor antenna SMA female type USB port 1 port for debugging behind blend Operating Temperature 5 to 50 Storage Temperature 5 to 50 Operating Humidity 5 to 90 IP Rate IP30 Wall Bracket Size Dimension W x H x D 61 8 x 103 x 6 mm Weight 16 g Mounting Type Wall mounting Colour RAL 9010 Material Poly Carbonate PC RF Specification Supported...

Page 22: ...DL 12 dBm Total 18 dBm Total UL 18 dBm Total 18 dBm Total Service Antenna Gain DL 2 dBi 6 dBi Gain w o Antenna Gain DL max 64 dB max 72 dB UL Noise Figure UL max 8 dB max 8 dB Flatness Passband ripple 4dB p p 4dB p p EVM max 3 5 256QAM max 8 64QAM max 3 5 256QAM max 8 64QAM VSWR max 2 0 1 max 1 5 1 Delay max 3 5 us max 2 5 us AGC Response Time 100 to 300 ms 100 to 300 ms AGC Error and Control Step...

Page 23: ...own for 30 mins Solid red while fully shutting down This alarm is raised when output power is over 3 dB than rated output power 1 8GHz 15 dBm 3 5GHz 21 dBm Access to the LMT and check in output status If the input power is normal but the output power reaches up to upper limit check the device output up per limit level is set correctly If the input power is strong rotate a Donor Antenna di rection ...

Page 24: ... raised when the isolation is not sufficient between antennas Change the location of the repeater or change the loca tion of the antenna 3 5GHz TDD Sync Solid red This alarm is raised when SSB fre quency change SSB index change Low Input RSRP Low SINR PSS or other unknown issue occurs Check cable connection status between a Donor An tennas Check the input signal is detected correctly using LMT Loc...

Reviews: