8
InstallatIon and oPERatIon ManUal FoR sl2 solaR ModUlEs oF tHE GEnERatIon G2.1 and G2.2
2.3 mountIng optIons
Approvedclampareasandmountingoptionsforthesolarmodules(topview).Thespecifieddimensions(inmm)refertotheclearance
between the module edge and the middle of the clamp. The illustrated mounting variants apply for installation in portrait and landscape
format.
unframed modules
mounting with clamps
Insertion profile system
The mounting option described for unframed modules is permitted only with point mounting.
solibro slide-In
The mounting option described for unframed modules is permitted with linear mounting.
With all of the options, the module can bend by up to 15 mm at the maximum permissible load. And the glass must not come into
contact with the substructure in this case.
PermissiblecontactareasforSlide-Inandinsertionprofilesystems
WhenfixingtheSlide-Inandinsertionprofilesystems,thepermissiblecontactareasmustbeobserved.Self-cleaningoftheframed
modulesisensurediftheyareinclinedatanangleof≥25°.
Inthecaseofinsertionprofilesystems,themodule’sowndeadweightholdsitinposition.Itisvitalthatyoutakeintoaccountthe
dynamic wind loading here, to ensure that the modules cannot not slide out or slip.
clamp area [x]
Substructure lateral
Point mounting
clamp area [x]
Substructure longitudinal
Point mounting
Design load
Permissible static
load [Pa]
Test load with
safety factor
γ
m
=1.5 [Pa]*
240 mm ± 25 mm
240 mm ± 25 mm
1,600
1,600
2,400
2,400
clamping area Substructure
clamp area [x]
Substructure longitudinal
Point mounting
Design load
Permissible static
load [Pa]
Test load with
safety factor
γ
m
=1.5 [Pa]*
50 mm ± 20 mm
1,600
1,600
2,400
2,400
consistent linear
positioning throughout
Design load
Permissible static
load [Pa]
Test load with
safety factor
γ
m
=1.5 [Pa]*
1,600
1,600
2,400
2,400
2 plannIng
x
x
L/2
x
≥80