requirements on the clamping system for unframed modules
only clamp systems approved by Solibro may be installed. The
list of all approved clamps is available at www.solibro-solar.com.
on request, Solibro can test clamp systems and approve them
following successful testing.
¼
All contact between the metal of the clamps and the module
glass must be prevented.
¼
use a suitable silicone-free rubber support plate between the
module and the substructure or clamps. The plate must be at
least 3 mm thick on the sides that are in contact with glass.
¼
The rubber mixture used as insulation material must have a
volume resistivity of at least 1*10
14
Ω*cm,inaccordancewith
ASTM D257.
¼
The material hardness of the rubber support plate should lie
between 45 and 75 on the Shore A scale.
¼
Ensure that the rubber mat is in place completely and does
not slip.
¼
The rubber support plate must be uv and aging resistant for
at least 25 years.
¼
Clampwidth:≥120mm.
¼
The clamp height of 7.3 mm (module thickness), including the
compression of the EPDM rubbers, may not be fallen short of
in the mounted state.
¼
clamps must not throw a shadow on the active cells.
Distancefromtheglassedgetothefirstactivecell
amounts to 16.5 mm (Fig. 3).
¼
comply with the glass inset (Fig. 3):
10–15 mm on the top side of the module
12–16 mm on the bottom side of the module
¼
comply with the side clearance between the edge of the glass
and the inner side of the clamps:
> 1 mm at 25 °c for thermal expansion of the module (Fig. 3)
Ensure that the screw connection does not apply any
additional tension to the module. The modules must be po-
sitionedstrainlessandfloat-mounted.Thescrewbetween
theglass/glassmoduleandtheclampshouldbetightened
with the recommended torque of 8 to 10 nm.
¼
See applicable documents “List of approved clamps and
mounting systems”
Fig. 3
clamping of unframed modules
10–15
12-16
16.5
7.3
±
0.5
> 1
clamp (schematic)
Glass (module top side)
Rubber
Glass (module bottom side)
Active surface
2 plannIng