background image

REMOTE CONTROL AND OPERATION

 

 7 

This mode is not available on this model. 

Press the ON/OFF button to turn the 
unit on and off. 

Press the SPEED button to cycle 
through the fans speeds: High, Low, & 
Mute 

Press the TURBO button to engage 
turbo mode. In turbo mode the Plasma 
Generator is engaged and the fan 
speed runs at the fastest speed. This 
mode quickly cleans the air. 

 

Hold the LOCK button for over 2 sec-
onds to lock the remote control. To 
unlock the remote, press the LOCK 
button again for more than 2 seconds. 

 

To program the unit to automatically 
turn off, press the TIMER button when 
the unit is on. The timer can be set for 
1, 2, or 4 hours. 

To program the unit for Auto-on turn on, 
press the TIMER button when the is off. 

 

Press the ODOR button to engage odor 
mode. In odor mode the Plasma Genera-
tor is engaged and the fan speed runs at 
the fastest speed. You can change the fan 
speed in odor mode. 

Press the ANION button to engage anion 
mode. In anion mode the negative ion Gen-
erator is engaged and the fan speed runs 
at low speed. You can change the fan 
speed in odor mode. 

 

Press the SLEEP button to engage sleep 
mode. In sleep mode the fan speed runs 
at mute or low speed depending on air 
quality. You cannot change the fan speed 
in sleep mode. 

 

Press the AUTO button to engage auto 
mode. In auto mode the unit automatically 
adjust the plasma generator according to the 
air quality. You cannot change the fan speed 
in auto mode. 

 

Press the LUM button to the brightness of 
the LED indicator lights. With each press 
the lights will adjust between bright-dark-
dark-bright. The Sensor lights will cycle 
between bright-dark-off. 

Low 

High 

Mute 

Summary of Contents for AH1-CC-01

Page 1: ...AH1 CC 01 HEPA Air Purifier Operating Instructions ...

Page 2: ...d this owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 4 inches clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly g...

Page 3: ... INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN PACKAGE CONTENTS Air Purifier HEPA Filter Cotton Filter Cotton Filter Replacements 3 inside unit Carbon Filter Inside unit Remote Control 1 Lithium CR2025 Battery Operating Instructions 3 MODEL AH1 CC 01 Recommended Cleaning Area 380 sq ft Power Consumption W Turbo High Low Mute 62 48 4...

Page 4: ...L MODE POWER BUTTONS PARTICULATE FILTER HEPA COLD CATALYST FILTERS DUST FRAME AIR INTAKE HEPA COLD CATALYST HOLDER ACTIVATED CARBON FILTER CARBON FILTER AIR PURIFIER HOLDER BODY POWER CORD REMOTE HOLDER HANDLE AIR EXHAUST PLASMA NEGATIVE ION GENERATOR ...

Page 5: ... Cold Catalyst Filter from the package 5 Insert HEPA Cold Catalyst Filter into the holder 6 Place the HEPA Cold Catalyst Filter Holder back into the unit 7 Place the Dust Frame back into the unit 8 Close the Front Panel 9 Remote Remove the battery holder in the Remote Control 10 Place the battery inside the holder Make sure to align the battery according to the image to the right 5 1 2 3 4 5 ...

Page 6: ...r To program the unit to automatically turn off press the TIMER button when the unit is on You can select either 1 2 or 4 hours with the Timer Each press of the TIMER button changes the shut off time Once the desired time 1 2 or 4 hours is over the unit will automatically shut down If you decide not to use the timer press the TIMER button until none of the timer indicator lights are lit on the con...

Page 7: ... off Press the ODOR button to engage odor mode In odor mode the Plasma Genera tor is engaged and the fan speed runs at the fastest speed You can change the fan speed in odor mode Press the ANION button to engage anion mode In anion mode the negative ion Gen erator is engaged and the fan speed runs at low speed You can change the fan speed in odor mode Press the SLEEP button to engage sleep mode In...

Page 8: ...st particulate filter you may clean this filter with warm water Do not wash the HEPA Cold Catalyst or Carbon filters If dust re mains on these filters you may use a cleaning rag or brush to remove the ex cess dust 8 When finished re install all necessary components 9 Once the unit is re assembled use a vac uum hose attachment to clean the sensor holes on the front of the air purifier 8 1 2 3 4 5 A...

Page 9: ...ers is facing outwards After the HEPA filter is re placed the change HEPA light will turn off For prolonged use clean every 3 months with a vacuum hose attachment 3 Activated Carbon Filter The activated carbon filter should last between 2 3 years If the filter begins to smell remove the filter and place in the sun for 3 5 hours If the smell is still present after sitting in the sun replace the Act...

Page 10: ...ng the air intake and or exhaust Remove any obstacles that are obstructing the air intake and or exhaust Filters need to cleaned replaced Clean replace the filters that maybe clogged with dust and debris The unit smells Clean or replace the activated carbon filter There is interference with the TV and or nearby lights are flickering The unit is too close to the TV and or fluorescent lights Move th...

Page 11: ... wear Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc Freight and Insurance cost for the warranty service Filter and Accessories ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL O...