Before installing the product check the following points: (1) the fan impeller turns freely and (2) there are no obstructions 

to the airflow.

All models include a robust mounting bracket which enables easy and quick installation of the fan. See

 Figure (2) 

Instal-

lation 

Diagrams For TD - MIXVENT Duct Fans.

Ductwork connection should be made with duct tape or duct fast-clamps (available through your local distributor) to en

-

sure a good seal and secure connection.

ELECTRICAL CONNECTION

All TD - MIXVENT series fans operate from a standard 120V 60Hz A.C electrical supply. All wiring must be carried out in 

accordance with National Electrical Code and all applicable state and local buildings codes. 

Electrical connections should be made in accordance with the following diagrams:

 Figure (3) 

Electrical Wiring.

MAINTENANCE

IMPORTANT:  BEFORE  CARRYING  OUT ANY  MAINTENANCE  OR  SERVICING,  ENSURE  THE  UNIT  IS  DISCON

-

NECTED FROM THE MAIN ELECTRICAL SUPPLY.

All TD - MIXVENT series exhaust fans incorporate sealed for life bearings and therefore do not require any lubrication. 

We would recommend inspection of the product at least once every twelve (12) months to avoid the excessive accumula

-

tion of dust and dirt on the impeller. To inspect the unit disconnect from electrical supply and remove from ducting. If any 

debris is evident on the impeller clean with a damp (not wet) cloth. DO NOT USE any detergents or abrasive materials 

for cleaning.

WARRANTY

JencoFan warrant that the TD - MIXVENT series exhaust fan will be free from defective materials and workmanship for 

the period of (5) years from the date of original purchase. In the event that we find any part is defective the product will 

be repaired or, in the Company’s discretion, replaced without charge provided that the product has been installed in ac

-

cordance with the enclosed instructions and all applicable EPA Standards and state and local building codes. JencoFan 

TD Bath Kits have an extended warrranty period of (7) years from the date of original purchase.

IF CLAIMING UNDER WARRANTY

Please return the complete product, freight paid, to you local authorized distributor. All returns must be accompanied by 

a valid Bill Of Sale. All returns must be clearly marked “Warranty Claim,” with an accompanying description stating the 

nature of the fault.

THE FOLLOWING WARRANTIES DO NO APPLY

Damages from shipping, either concealed or visible. Claim must be filed with the carrier.

Damages resulting from improper wiring or installation

Damages caused by acts of nature, or resulting from improper consumer procedures such as: Improper Maintenance; 

Misuse; Negligence; Alteration; Abuse; Abnormal Use; or Accident or Incorrect Electrical Voltage and Current.

Removal or alteration to the JencoFan data plate label. 

WARRANTY VALIDATION

The end user must keep a copy of the Bill of Sale to verify purchase date.

THE ABOVE FIVE (5) YEAR WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, WRIT

-

TEN OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE. IN NO EVENT 

SHALL JENCOFAN

 BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING 

LOSS OF PROPERTY, REVENUES, LOST PROFITS, COSTS OF REMOVAL, INSTALLATION OR REINSTALLATION.

6

Summary of Contents for TD-125

Page 1: ...URS HELICOCENTRIFUGES EN LIGNE Models TD 100 TD 100X TD 125 TD 150 TD 200 TD 200X TD 250 TD 315 INSTALLATION AND WIRING INSTRUCTIONS INSTRUCCIONES DE MONTAJE INSTRUCTIONS DE MONTAGE English Español Français READ AND SAVE THESE INSTRUCTIONS LEER Y GUARDAR ESTAS INSTRUCCIONES LIRE ET CONSERVER CES INSTRUCTIONS ...

Page 2: ......

Page 3: ... the mounting bracket fan flange assembly to a fixed structure Fijar el pie soporte a la pared o techo Fixez le pied support au mur ou au plafond 3 Replace the fan motor wheel assembly and tighten the two spring clips to secure the product Volver a montar el cuerpo motor en su pie de soporte con las dos bridas y apertar los torni llos Remontez le corps moteur sur son pied support avec les deux bri...

Page 4: ...ANTE TODOS LOS TD MIXVENT INCORPORAN UN MOTOR 120V 60Hz DE DOS VELOCIDADES LA FASE TIENE QUE CONECTARSE ÚNICAMENTE AL TERMINAL HI O LO NO A LOS DOS A LA VEZ Figure 3 Electrical Wiring Conexión Eléctrica Branchement Electrique TD MIXVENT flow Motor without Speed Controller Motor sin regulador de velocidad Moteur sans régulateur de vitesse Models TD 100 100x 125 150 200x are double insulated and are...

Page 5: ...to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel c Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes standards including fire rated construction d Sufficient air is needed for proper combustion and e...

Page 6: ... free from defective materials and workmanship for the period of 5 years from the date of original purchase In the event that we find any part is defective the product will be repaired or in the Company s discretion replaced without charge provided that the product has been installed in ac cordance with the enclosed instructions and all applicable EPA Standards and state and local building codes J...

Page 7: ...ión para que no se pueda conectar de nuevo accidentalmente Si no se puede acerrojar el sistema de desconexión fijar firmemente un panel de advertencia muy visible al cuadro de mandos c La instalación y la conexión eléctricas deben ser realizadas por un profesional cualificado de acuerdo con las normativas y reglamentos vigentes incluyendo las construcciones clasificadas al fuego d Prever la cantid...

Page 8: ...oductos abrasivos para limpiar DE GARANTÍA JencoFan garantiza los ventiladores de la serie TD MIXVENT contra los defectos de fabricación o de materiales por un periodo de cinco 5 años a partir de la fecha de adquisición En el caso de que una pieza sea defectuosa el producto será reparado o reemplazado sin cargo siempre y cuando éste haya sido instalado de acuerdo con las instrucciones adjuntas y d...

Page 9: ...débranchez le du secteur au niveau du tableau de commandes et verrouillez le système de déconnexion afin d éviter que l appareil ne soit accidentellement reconnecté Si le sys tème de déconnexion ne peut être verrouillé fixez et assurez un panneau d avertissement très visible au tableau de commandes c L installation et le branchement électriques doivent être réalisés par un professionnel qualifié e...

Page 10: ...a turbine au moins une fois par an Pour inspecter l appareil débranchez le du secteur électrique et des conduits En cas d encrassement de la turbine nettoyez la avec un linge humide mais pas mouillé N utilisez pas de détergent ou de produits abrasifs pour le nettoyage DE GARANTIE JencoFan garantit les ventilateurs de la série TD MIXVENT contre les défauts de fabrication ou de matériaux pour une pé...