2.
ODU transmit power in dBm
3.
ODU receive frequency in KHz
4.
ODU Receive RSSI in dBm
5.
ODU temperature in degrees C
6.
Demod frequency in Hz (a loop stress indicator from the carrier recovery loop)
7.
Demod SNR in dB
8.
IF Receive Power at IDU-ODU IF interface in dBm
9.
Demod lock indication (1 = locked, 0 = unlocked)
10.
Demod loopback configuration (1 = loopback, 0 = normal)
11.
IDU Software Alarm (1 = alarm, 0 = no alarm)
12.
ODU Alarm (1 = alarm, 0 = no alarm)
13.
IP Address
14.
Modem transmit state (0 = unconfigured, 1 = configured, 2 = operating, 3 = error)
15.
Modem receive state (0 = unconfigured, 1 = configured, 2 = acquiring, 3 = operating, 4 =
error)
16.
IDU Hardware Alarm (1=alarm, 0= no alarm)
17.
Mainboard Temperature in degrees C
18.
Power Supply Temperature in degrees C
6.14
System
The System screen contains the system information other than the modem and radio parameters. Due to
the large amount of information, there are seven different separate screens.
6.14.1
Version Information
The system contains firmware on an FPGA. The version and type (Application) of the FPGA code is
indicated there for diagnostic purposes. Also, serial numbers of the IDU components are shown on this
screen. Only the
Unit
Serial Number need to be referred to in diagnostics purposes. The other
numbers are for factory purposes only.
Summary of Contents for SKYWAY-LM Series
Page 1: ...1 SKYWAY LM SERIES PTP Microwave Radio System User s Guide APRIL 2010 Rev 1 6 PN 1552601 ...
Page 21: ...21 Figure 5 2 The backside of the ODU rectangular waveguide version shown ...
Page 25: ...25 Figure 5 9 Loosened plate Figure 5 10 Rotating the antenna waveguide by 90 degrees ...
Page 50: ...50 Figure 6 19 System Reboot Screen ...
Page 57: ...57 Figure 8 3 Serial Interface Menu Structure ...