Setting
Setting
68
69
(g-4)
(g-4-1)
(g-4-2)
(g-4-3)
(g-4-4)
g-4-1) Reset Errorlog
Select "Yes" to reset all error records on the inverter.
Reset
>No<
Reset Errorlog
g-4-2) Reset Meter Energy
User can reset the meter energy record here.
>Reset Meter1
No
Reset Met Energy
g-4-3) Reset Load
User can reset the specific load’s energy if the inverter is installed with a
smart plug.
Reset Load1
>No<
Reset Load Consume
Reset
Reset Meter Energy
Reset Load
Config Guide
Reset Errorlog
Reset Inv Energy
Factory Reset
(g-4-5)
(g-4-6)
g-4-4) Config guide
This page will show the setup guide.
>Start
Config Guide
Meter Setting
(g-5)
Disable
MeterSetting
g-5) Meter Setting
X3-Retro Fit inverter with Energy meter connected can achieve hybrid functions.
You can disable the meter function then it can work as a normal grid-tied inverter
without PV and meter connected. In retro fit system, if you would like to monitor
the other PV inverters as well, you can install meter on both X3-Retro fit and the
others. The two meters shall have different address. Address 001 and address 002
are already written into meters by default, so do not make any change to the
address except for specific situation.
MeterSetting
MeterSetting
1
2
>MeterFunction
>Meter1Addr
>Meter2Addr
g-4-5) Reset Inv energy
Select "Yes" to reset all energy records on the inverter.
>Reset
Reset Inv Energy
g-4-6) Factory reset
Select "Yes" to reset the inverter settings back to factory default.
>Factory Reset
Fcatory Reset
NO
NO