5.3 Installation Precaution
Please avoide direct sunlight, rain exposure, snow laying up during installing and
operating.
Available Space Size
X1 Series inverter is designed for outdoor installation (IP 65).
Make sure the installation site meets the following conditions:
Not be exposed to glare.
Not in areas where highly flammable materials are stored.
Not in potential explosive areas.
Not in the cool air directly.
Not near the television antenna or antenna cable.
Not higher than altitude of about 2000m above sea level.
Not in environment of precipitation or humidity(100%) .
Be sure the ventilation is good enough.
The ambient temperature in the range of -25
℃
to +60
℃
.
The slope of the wall should be within
±
5
°
.
Position
Min.size
Ø
Left
300mm
300mm
300mm
300mm
300mm
Right
Top
Bottom
Front
Table Available Space Size
5.4 Installation Steps
Preparation
Step 2: Screw the wall bracket on the wall
Step 3: Match the inverter with wall bracket
Ø
Ø
Ø
Below tools are needed before installation.
Installation tools : crimping pliers for binding post , screwdriver, manual
wrench and
Φ
10 driller.
b) Use the wall bracket as a template to mark the position of the 3 holes
on the wall.
c) Drill holes with driller, make sure the holes are deep enough (at least
50mm) for installation, and then tighten the expansion tubes.
d)
Install the expansion tubes in the holes, and tighten them. Then install
the wall bracket by using the expansion screws.(
Φ
10 driller.torque: 0
.
8
±
0
.
1Nm)
e) Hang the inverter over the bracket, move the inverter close to it, slightly lay
down the inverter, and make sure the 3 mounting bars on the back are fixed
well with the 3 grooves on the bracket.
Note: Please refer to the details from the Quick Installation Guide.
16
Installation
Installation
The wall hanging the inverter should meet conditions below:
1) Solid brick/concrete, or strength equivalent mounting surface;
2) Inverter must be supported or strengthened if the wall’s strength isn’t enough(such
as wooden wall, the wall covered by thick layer of decoration)
17
300mm
300mm
300mm
300mm
X1
Step 1: Unscrew the bracket from the back of the inverter.
Ø
a) The wall bracket is fixed on the inverter, and the user should remove it
firstly.
(Φ
10 driller.torque: 0
.
8
±
0
.
1Nm)