6.2.3 Battery Connection
BAT terminal connection
Ø
CAUTION!
DANGER — HIGH VOLTAGE!
Make sure the breaker of battery is in OFF position.
Charging and Discharge system of A1-HYB-G2 series inverter is designed for high-
voltage lithium-ion battery.
Battery connection diagram for Lithium-ion battery
Ø
CAUTION!
Never reverse the polarity of the battery cables as this will result
in inverter damage. Always ensure correct polarity.
A1-HYB-G2
Series Inverter
Lithium-ion Battery
BAT Port
BMS Port
Electrical Connection
Electrical Connection
45
44
As a Lithium-ion battery will be connected with HYB series inverter, the battery
communication should be compatible with A1-HYB-G2 series inverter and the BMS
must be connected between inverter and battery.
2 Make sure that both ends of the cables are connected correctly to the connector
on the right side of the BMS module.
A: BAT+ B: Communication connection C: BAT-
1 The BAT+ (red) , communication cable and BAT- (black) cables have been
already connected on the inverter’s side. Only connecting the other end of the
cables to the corresponding port of BMS is needed.
DIP
BMS
BAT+
BAT-
POWER
A
B
C
A
B
C
On the side of battery
Inverter
Battery