16. Install the plenum as shown below, the front studs
will be inserted into the plenum stud brackets until
they make contact with the plenum (as shown in
“Detail B”). Secure the front studs to the plenum
stud brackets using the (4) #10 self-drilling sheet
metal screws per stud provided.
17. Once the front studs have been secured to the
plenum, confirm that the plenum is level front to
back and side to side. Once the plenum is level,
secure the rear studs to the plenum stud brackets
using the (4) #10 self-drilling sheet metal screws per
stud provided.
18. Once the plenum has been installed, connect the
ducts to the plenum and secure to the collector
using the 5” hose clamps provided.
19. Once the unit has been enclosed within the wall
the “Plenum Outlet Trim” will be press fit into
the plenum outlet opening. Apply some high
temperature RTV/silicone during the installation of
the “Plenum Outlet Trim” to insure it is secured in
place.
INSTALLATION
B
DETAIL B