5 Use and operation
5.4.7 Manual operation
Function: Test (correct wiring, function) of the indi-
vidual components possible, such as electric heating
element, primary circuit pump, fan.
i
Use this screen only for commissioning and
service work by qualified personnel.
Abb. 2-18
5.4.8 Qualified personnel menu
Abb. 2-19
1 Service menu
2 IP-VNC (IP address of the control)
3 Sending emails
4 mySOLARFOCUS app
5 Language selection
6 Date and time
5.4.8.1 Service menu
In the
Service menu
there are technical (factory pre-
defined) settings. These can only be accessed by
qualified personnel (code input required).
5.4.8.2 IP-VNC
The IP address must be must be entered in order to
operate the control via the internet.
The following control functions require internet acces-
sibility.
–
Remote access to the control
–
mySOLARFOCUS app
–
Weatherman function
–
Sending emails
–
Photovoltaic self-consumption optimisation (see
manual DR-9960)
Hardware
A cable connection is required on site for connecting
the control to the router. Use the Ethernet socket
(type RJ45) on the rear of the control panel (Touch
display).
IP configuration
screen
►
To access the
IP-VNC
icon, select the following
in the control
–
Selection menu
screen
–
Customer menu
screen
–
Qualified personnel button
►
Enter the data for your router. Recommended
process:
–
Select
DHCP ON
.
Ä
The IP address is determined automatically.
–
Select the
DHCP OFF + Adopt
button.
–
The IP address must be unique in each Ethernet
network and is dependent on the other network
components (PC, modem/router, etc.).
–
Recommendation: Set a fixed IP address
(=
DHCP OFF
), i.e. the control has a constant IP
address.
5.4.8.3 Sending emails
Function: The
eco
manager-
touch
control automatically
sends status emails and alarm e-mails (to stored
addresses) if required.
Status email
: An automatic email (e.g. sent daily) pro-
vides information on the current heat pump status.
Alarm email
: a message is sent when a fault occurs.
i
Installation and configuration of this function
must be performed by the customer (i.e. not
included in the commissioning, service and
support activities).
16
Operation manual
vampair