Electrical connection
18
Installation manual
pellet
top
7.6 Other connections
External boiler request (X28)
Potential-free relay output for switching an external boiler, for example, an external boiler
receives a release from the SOLARFOCUS boiler control;
connect to X28 on SOLARFOCUS power element.
Attention!
The connection is potential-free and has a maximum load of 5A.
Fault (X29)
Potential-free relay output, for example, to switch a warning device (optical/acoustic) upon
occurrence of an operating fault on the boiler;
connect to X29 on the power element.
Attention!
The connection is potential-free and has a maximum load of 5A.
External request (X51)
Input, i.e. the SOLARFOCUS boiler can be started by an external control;
connect to X51 on the power element.
Attention!
This connection must be potential-free.
Connect the heating circuit pump (X9, X10)
Connect heating circuit pump 1 to power element connector
X9
and heating circuit pump 2
to
X10
.
If required (e.g. in the case of underfloor heating), connect a limiting thermostat.
If a limiting thermostat is not used, the contact must be bridged.
7.7 Internet connection
To connect the boiler control with the Internet, connect the Ethernet port
X2
(type RJ45) on the back of the dis-
play with a network router via cable. The connection is required in order to use the following functions:
- mySOLARFOCUS app
- Weatherman function
- IP-VNC (Remote access to the boiler control)
- Sending e-mails
7.8 Types of sensors - overview
Measuring
sleeve
Cable
Sensor type
Art.No.
Use
Colour
Material / finish
Length
15 cm
silver
Stainless steel braid
3 m PT100
69688
Flue gas temperature sensor (pellet
plus
, octo
plus
,
thermi
nator
I)
1.6 m PT100
69681
Flue gas temperature sensor (thermi
nator
II 22-30)
2.1 m PT100
69682
Flue gas temperature sensor (thermi
nator
II 36-60,
pellet
top
, pellet
plus
)
1 m PT100
69680
Feed sensor rotary valve (pellet
top
, octo
plus
)
13 cm
grey
PVC cable
2 m PT1000
1622
Flow sensor for fresh water module
fast
5 cm
red
Silicone cable
2.1 m PT100
69687
Feed sensor pellets / wood chips feed
red
Silicone cable
3 m KTY81-110
69686
Return sensor, boiler temperature sensor, external
boiler sensor
black
PVC cable
3 m KTY81-110
69095
Tank sensor
PVC cable
5 m PT1000
69095-1000 Tank sensor
black
PVC cable
5 m PT1000
69098-1000 Flow sensor
Silicone cable
5 m KTY81-110
69689
Return sensor pellet
top
70
2 cm
grey
PVC twin cable
2 m PT1000
1621-PT
Tank sensor
white
PVC twin cable
2 m KTY81-210/B
1621
Tank sensor
red
Silicone cable
2 m KTY81-210/B
1620
Collector sensor
black
Silicone cable
2 m PT1000
1620-PT
Collector sensor
2 cm x 1.5 Ø
Contact sen-
sor
black
PVC cable
2 m KTY81-110
69098
Flow sensor
-
-
to be provided on-site
-
KTY81-110
69096
External sensor; (plastic housing 66x60x39 mm)
-
-
to be provided on-site
-
PT1000
69096-1000 External sensor; (plastic housing 66x60x39 mm)
Summary of Contents for pellet top touch 35
Page 26: ...Annex 26 Installation manual pellettop 9 6 Commissioning log...
Page 27: ...Annex Installation manual pellettop 27...
Page 28: ...Annex 28 Installation manual pellettop 9 7 Customer service order form...
Page 29: ...Annex Installation manual pellettop 29...
Page 30: ...Annex 30 Installation manual pellettop...