2 Safety information
3.1.3 Cessation of entitlements
The maintenance, warranty and guarantee services
expire if one of the following points applies:
–
Non-compliance with the technical requirements
–
Damage during transport.
–
Wilful damage.
–
Damage due to force majeure (water, fire, etc.).
–
Non-observance of information in the planning,
installation and operation manual.
–
Insufficient energy or water, fault in the hydrau-
lics.
–
Incorrect operation and failure to perform main-
tenance and cleaning as prescribed.
–
Commissioning and maintenance carried out by
non-certified companies.
–
Undocumented commissioning (missing com-
missioning protocol) and/or maintenance (main-
tenance protocol).
–
It is almost impossible to produce flawless pain-
ted parts; for this reason, slight defects that do not
adversely affect proper use shall not be deemed
as grounds for complaint.
–
No claims can be accepted under the warranty if
unauthorised intervention (or action that has not
been explicitly approved by us) has been carried
out. In addition, the goods must be paid for within
the specified payment timeframe.
3.1.4 Limitation of liability
SOLARFOCUS GmbH assumes no liability for injury
or material damage resulting from:
–
Failure to observe the instructions in this manual.
–
Use of the product for any purpose other than for
its intended use.
–
Deployment of unqualified personnel.
–
Use of non-approved spare parts.
–
Technical modification of the product by the sys-
tem operator.
3.2 Standards, guidelines, regulations
The following bodies of regulations must be con-
sidered and adhered to during planning, installation
and operation of the heating system:
Standards for heating systems
–
EN 303-5
- Part 5: Boilers for solid fuels, manually
and automatically fed firing systems, nominal
heat output up to 500 kW
–
DIN EN 12828
Heating systems in buildings - plan-
ning for water-based heating systems
–
EN 13384- 13384
- Flue gas systems - thermal
and flow-based calculation methods- 1: Exhaust
systems with one fireplace
–
ÖNORM H 5151
- Planning of central hot water
heating systems with or without hot water pre-
paration - Part 1:
–
–
Simple inspection of combustion plants for solid
fuels
Standards for structural and safety installations
–
TRVB 118 H
- Technical Guidelines for Pre-
ventive Fire Protection (Austria)
–
ÖNORM H 5170
- Heating systems - requi-
rements for construction and safety technology as
well as for fire and environmental protection
–
ÖNORM M 7137
- Pressed natural wood pellets -
Wood pellets - Requirements for pellet storage at
the end-user
Standards for fuel
–
EN ISO 17225-2
- Biogenic solid fuels - Fuel spe-
cifications and classes; Part 2: Classification of
wood pellets
–
1. BImSchV
- Federal Immission Control
Ordinance - Ordinance on Small and Medium
Solid-fuel Boilers()
Standards for the heating water
–
ÖNORM H 5195-1
- Heat transfer media for buil-
ding services systems, Part 1: Preventing
damage from corrosion and scale formation in clo-
sed hot water heating systems(Austria)
–
VDI 2035
- Prevention of damage in hot water
heating systems (Germany)
–
SWKI BT 102-01
- Water quality for building ser-
vices installations (Switzerland)
–
UNI 8065
(Italy)
3.3 Installation room
Structural specifications
–
The boiler may only be installed in a dry, frost-free
room; the permissible room temperature is 5 to
30°C.
–
The boiler may only be used on a sufficiently sta-
ble and non-combustible surface.
–
Observe spacing to flammable materials (regional
regulations).
–
Note the installation dimensions to ensure suf-
ficient space is provided (e.g. for service and
maintenance work).
–
For normative specifications see ÖNORM H 5170
and guideline TRVB 118 H.
Installation manual
ecotop-zero, ecotop-light
5