2 Safety information
4.4 Accessories
Lifting aid
–
Optional accessories for carrying/moving the boi-
ler
–
Item 6144
Abb. 2-2: Lifting aid mounted
Extension for exhaust pipe connection
–
Accessory (included in delivery) for optional exten-
sion of the connection, from Ø100 mm to Ø130
mm.
–
Can be used for flue pipe orientation upwards or
backwards.
–
Art. 66556NIRO
►
Establish the chimney connection
►
Specifications for chimney design
4.5 Dimensioning of the boiler
The boiler must be correctly dimensioned in relation
to the heat distribution system behind it.
For a correct design, see calculations according to
standard EN 12828.
4.6 Functional components
1 Heating water, heating circuit (return/flow)
2 Flue gas pipe
3 Connections for pellets
4 Induced draft fan
5 Suction turbine for pellets suction
6 Electrostatic dust filter (optional at
ecotop
light
)
7 Intermediate pellet store
8 Boiler electrical power element
9 Ash container
10 Rotary valve
11 Differential pressure gauge
12 Heat exchanger with interior turbulators
13 Combustion grate
Installation manual
ecotop-zero, ecotop-light
11