7 Electrical connection
7 Electrical connection
DANGER
-
There is a risk of fatal electric
shocks when working on electrical
components of the system
–
Work may be performed only by a qualified
electrician.
–
Applicable standards and regulations must
be observed.
7.1 Voltage supply for the heating sys-
tem
–
A separate power circuit must be provided in the
Aufstellraum for the heating system.
–
Connection 230 V AC / 50 Hz C13 A
–
Specification for the mains connection cable (e.g.
in case of replacement): cable SIHF-J 3x1.5 mm²
7.2 Connections to the boiler power ele-
ment
Abb. 2-16: Boiler power element
To access boiler power element
1
:
►
Remove the right-hand side panel
Detailed illustration of the power element
Heating circuit 1
X9 Heating circuit pump 1
X11 Heating circuit mixer 1
X38 Flow temperature sensor 1
X41 optional: Room temperature sensor 1
X42 Outside temperature sensor
Heating circuit 2
X10 Heating circuit pump 2
X12 Heating circuit mixer 2
X37 Flow temperature sensor 2
X40 optional: Room temperature sensor 2
Buffer tank
X7 Special version: Buffer loading pump
X13 Return mixer
X15 Standard version: Return booster pump
X36 Bottom buffer sensor
X44 Top buffer sensor
DHW tank
X8 DHW tank pump
X39 DHW tank sensor
Recirculation control
X5 Recirculation pump
X43 Circulation sensor (optional)
Display
X53 Bus line to control unit (Display)
Mains connection
X1 Mains connection for power element, 230 V AC
X2 230 VAC output
X18 230 V AC output (F8 A fuse)
Pellet conveyor
X14 Motor of the pellet auger (for
auger conveyor
intake system
)
X14 Motor of the transfer auger (for
pellet box
)
Boiler
X3 Suction turbine
X4 Glow pencil (ignition device)
X16 Ash extraction motor
X19 Induced draft fan
X20 Overtemperature reset (OTR)
X23 Feeder motor
X24 Motor heat exchanger cleaning
X26 Primary air damper holding magnet
X27 Ignition supply air holding magnet
X31 Boiler temperature sensor
X32 Return temperature sensor
X34 Flue gas temperature sensor
X45 Lambda sensor
X47 Speed measurement induced draft fan
X48 Door contact switch
X49 Level sensor in pellet storage tank
Installation manual
ecotop-zero, ecotop-light
23