RJ45 Pin #
Wire Color
(1)
10Base-T Signal
100Base-TX Signal
T568B
T568A
1
White/Orange
White/Green
T
2
Orange
Green
Transmit-
3
White/Green
White/Orange
4
Blue
Blue
Reserved
5
White/Blue
White/Blue
Reserved
6
Green
Orange
Received-
7
White/Brown
White/Brown
Reserved
8
Brown
Brown
Reserved
Figure 25: Standard cable wiring
6. Use a pre-crimped cable to connect via gland #1 to the RJ45 plug on the inverter's
communication board or, if using a spool of cable, connect as follows:
a. Insert the cable through gland #1.
b. Remove the cable’s external insulation using a crimping tool or cable cutter and
expose eight wires.
c. Insert the eight wires into an RJ45 connector, as described in
d. Use a crimping tool to crimp the connector.
e. Connect the Ethernet connector to the RJ45 port on the communication board.
(1)
The connection does not support RX/TX polarity change. Supporting crossover Ethernet cables depends
on the switch capabilities.
Chapter 5: Setting Up Communication with the Monitoring Platform
42
Three Phase Inverter with SetApp Configuration