![SolarEdge SE10000H Installation Manual Download Page 75](http://html1.mh-extra.com/html/solaredge/se10000h/se10000h_installation-manual_1313722075.webp)
SE2200H
SE3000H
SE3500H
SE3680H
SE4000H
SE5000H
SE6000H
Units
OUTPUT
Rated AC Power Output
2200
3000
3500
3680
4000
5000
(1)
6000
VA
Maximum AC Power Output
2200
3000
3500
4000
4000
5000
(1)
6000
VA
AC Output Voltage (Nominal)
220 / 230
Vac
AC Output Voltage Range
184 - 264.5
Vac
AC Frequency (Nominal)
50 / 60 ± 5
Hz
Maximum Continuous Output Current
10
14
16
16
18.5
23
27.5
A
Maximum Continuous Overcurrent
Protection
10
14
16
16
18.5
23
27.5
A
Residual Current Detector / Residual
Current Step Detector
300 / 30
mA
Inrush current AC (Peak/Duration)
2.8 / 20
Aac
(rms) /
ms
Maximum Output Fault Current
38
A
Power Factor Range
1 (adjustable from -0.9 to +0.9)
Total Harmonic Distortion
< 3
%
Protective class
Class I
(1)SE5000H is limited to 4600VA in Germany
SolarEdge
-
Three Phase Inverter Specifications (Europe & APAC) MAN-01-00239-1.1
1
Technical Specifications - Single Phase Inverters with HD-Wave Technology