![SolarEdge SE10000H Installation Manual Download Page 74](http://html1.mh-extra.com/html/solaredge/se10000h/se10000h_installation-manual_1313722074.webp)
SE2500H SE3000 SE4000H SE5000H SE6000H SE8000H
SE10000H
Units
INSTALLATION SPECIFICATIONS
AC output conduit size / Wire cross section
19-25 mm / 1-13 mm
2
DC input conduit size / # of strings / Wire cross
section
19-25 mm / 1-2 strings / 1-13 mm
2
19-25 mm / 1-3 strings
/ 1-13 mm
2
AC Terminal Block Cross Section
1-13
mm
2
Dimensions with Safety Switch (HxWxD)
450 x 370 x 174
540 x 370 x 185
mm
Weight with Safety Switch
10
11.4
11.9
17.6
kg
Cooling
Natural Convection
Operating Temperature Range
(1)
-40 to +60
°C
Noise
< 25
< 50
dBa
Protection Rating
IP65 - Outdoor and Indoor
Recommended circuit breaker/ fuse size to use at the connection point of the SolarEdge inverter to the grid:
Inverter
Maximum output current (A) Minimum fuse rating (A) Maximum fuse rating (A)
SE2500H
12.5
16
50
SE3000H
16
20
50
SE4000H
18.5
25
50
SE5000H
23
32
50
SE6000H
27
40
50
SE8000H
48
63
80
SE10000H
48
63
80
(1)
Full power up to at least 50°C. For power de-rating information refer to:
https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf
3
Single Phase Inverters with HD-Wave Technology
Specifications
(
Australia
)
MAN-01-00
538
-1.
0