![SolarEdge OP250-LV Installation Manual Download Page 64](http://html1.mh-extra.com/html/solaredge/op250-lv/op250-lv_installation-manual_1313700064.webp)
Replacing and Adding System Components
SolarEdge Installation Guide – MAN-01-00002-1.6
64
Chapter 5
Replacing and Adding System
Components
Modifying an Existing Installation
This section describes how to modify an existing installation that has been
operating properly for a while.
►
To modify an existing installation:
1
Shut down the inverter by turning OFF its ON/OFF switch and the DC switch
of the main circuit board. The inverter goes into Shutdown mode and
displays the following message:
D C V O L T A G E N O T S A F E !
D O N O T D I S C O N N E C T !
V D C : 7 2 . 0
This message is displayed until the DC is safe. The default safety voltage is
50 V.
WARNING!
Do not touch the DC power connections until the DC voltage is at a safe
level. Doing so may cause personal damage, damage to the device and/or
danger of fire.
Ne pas touchez les connecteurs de courrant DC jusqu'à ce que la tension
DC soit tombée àun niveau sécurisé. Y touchez pourrait engendrer un
dommage aux personnes, un dommage à l'appareil ou un risque d'incendie.