Technical Specifications
SolarEdge Installation Guide – MAN-01-00002-1.6
112
OP250-LV
OP300-MV/
OP400-MV
Output During Operation (Power Optimizer Connected to Operating
Inverter)
Maximum Output Current
15
Adc
Operating Output Voltage
5 - 60
Vdc
Total Maximum String Voltage
(Controlled by Inverter) - US and
EU 1-ph
500
Vdc
Total Maximum String Voltage
(Controlled by Inverter) - EU 3-ph
950
Vdc
Output During Standby (Power Optimizer Disconnected from Inverter
or Inverter Off)
Safety Output Voltage per Power
Optimizer
1
Vdc
PV System Design
Minimum Number of Power
Optimizers per String (1 or More
Modules per Power Optimizer)
8 (1-ph system) / 16 (3-ph
system)
Maximum Number of Power
Optimizers per String (1 or More
Modules per Power Optimizer)
Module power dependent;
typically
20 - 25 (1-ph system)
45 - 50 (3-ph system)
Parallel Strings of Different
Lengths or Orientations
Yes
Standard Compliance
EMC
FCC Part15 Class B,
IEC61000-6-2, IEC61000-6-3
Safety
IEC-62103 (class II safety),
UL1741
Material
UL-94 (5-VA), UV Resistant
RoHS