If installing multiple inverters:
When installing inverters side by side, leave at least 20 cm between inverters.
When installing inverters one above of the other, leave at least 40 cm between
inverters.
3. Position the mounting bracket against the wall/ pole and mark the drilling hole
locations (refer to the
Mechanical Specifications appendix below for inverter and
mounting bracket dimensions).
4. Drill the holes and mount the bracket. Verify that the bracket is firmly attached to
the mounting surface.
5. Hang the inverter on the bracket:
a. Lift the inverter from the sides, or hold it at the top and bottom of the inverter
to lift the unit into place.
b. Lower the inverter onto the U-shaped indentations, as shown below. Let the
inverter lay flat against the wall or pole.
c. Insert the two supplied screws through the outer heat sink fin on both sides of
the inverter and into the bracket.
Tighten the screws with a torque of 4.0 N*m / 2.9 lb.*ft.
Figure 8: Hanging the inverter on the brackets
6. Optionally, secure the Connection Unit bracket to the wall/pole, using 3 screws:
NOTE
In case of inverter replacement with the Connection Unit still mounted, it is
recommended to use all 3 holes.
Chapter 3: Installing the Inverter
27
Single Phase Energy Hub Inverter MAN-01-00812-1.1
Summary of Contents for Energy Bank
Page 68: ......