NOTE
Make sure the mounting surface or structure can support the weight of the
inverter.
CAUTION!
SolarEdge inverters and Power Optimisers can be installed at a minimum
distance of 50 m/ 164 ft from the shoreline of an ocean or other saline
environment, as long as there are no direct salt water splashes on the inverter or
Power Optimiser.
For SolarEdge inverters installed at a distance of 200 m / 655 ft or closer to the
shoreline, special brackets purchased separately from SolarEdge and SS304
stainless screws are required.
1. Determine the inverter mounting location, on a wall, stud framing or pole. It is
recommended to mount the inverter in a location protected from direct sunlight.
2. To allow proper heat dissipation, maintain the following minimum clearance areas
between the inverter and other objects:
Figure 7: Clearance areas
If installing a single inverter:
20 cm from the top of the inverter.
At least 10 cm from the bottom of the inverter.
10 cm from the right and left of the inverter.
Single Phase Energy Hub Inverter MAN-01-00812-1.1
26
Mounting the Inverter
Summary of Contents for Energy Bank