- 28 -

15. Warranty

SolarAttic

Limited Warranty-PCS

All Pool Convection System (PCS) pool heaters are warranted to be free from manufacturing defects for
a period of thirty-six (36) months from the date of first consumer installation or fifty-four (54) months
from the date of shipment from the factory, whichever occurs first.  The consumer must complete and
return the warranty registration card and provide a receipted bill of sale as proof of warranty period
within 30 days from the date of installation.  Without registration and proof of purchase date, the war-
ranty begins on the date of shipment from the factory.  This Limited Warranty covers parts and labor to
correct manufacturing defects only.  It does not cover incidental fin damage nor any corrosive damage
to heat transfer coils caused by improperly maintained chemical levels in pools.  Ph levels outside the
7.2 to 7.6 range voids warranty.  Use in Ocean or Sea water pools voids warranty.  Use in pools utiliz-
ing salt, as a source of chlorine, does not void warranty.  All chemical dispensers must be plumbed
downstream.  Dispensing pool chemicals directly into the pool heater voids warranty.  Failure to proper-
ly winterize the pool heater in areas with freezing temperatures voids warranty.  This warranty does not
cover winter freeze damage, normal maintenance, labor charges for removal or installation of parts,
transportation charges to the factory or for any other service calls or repairs.

Corrugated fins are used on the heat transfer coils for improved efficiency.  They are waffled in appear-
ance and not straight.  Fin bending that has been combed with a fin tool does not affect performance
and is not considered a manufacturing defect.  Our obligation under this warranty is limited to the repair
or replacement, at our factory, of any part which, upon our examination, has proven to be defective.
Correction of such defects by repair or replacement (at our option) and return freight via lowest com-
mon carrier, shall constitute fulfillment of SolarAttic’s obligation.  This warranty does not apply to
those products which, in SolarAttic’s  judgment, have been altered or repaired outside of our factory or
by unauthorized factory representatives, subjected to misuse, negligence, accident, corrosive atmos-
pheres, or operating beyond the limits of our design.

THIS WARRANTY CONSTITUTES THE BUYERS SOLE REMEDY.  IT IS GIVEN IN LIEU OF ALL OTH-
ER WARRANTIES.  THERE IS NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE.  WHERE CIRCUMSTANCES CAUSE REMEDY EXPRESSED HEREIN TO
FAIL OF ITS ESSENTIAL PURPOSE, SOLARATTIC’S LIABILITY SHALL NOT IN ANY EVENT EX-
CEED THE ORIGINAL PURCHASE PRICE.  IN NO EVENT, SHALL SOLARATTIC BE LIABLE FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES, WHETHER THE THEORY BE BREACH OF THIS OR
ANY OTHER WARRANTY, NEGLIGENCE, OR STRICTLY TORT.  DISPUTES ARISING UNDER THIS
AGREEMENT SHALL BE GOVERNED BY APPLICABLE MINNESOTA LAW.  THE VENUE FOR ALL
DISPUTES IS SWIFT COUNTY, MINNESOTA.

Model Number _________________________________________ 

Serial Number__________________________________________

Date of Installation ______________________________________  

Installer _______________________________________________

______________________________________________________

Summary of Contents for PCS3

Page 1: ...Installation and Operating Instructions SolarAttic Solar Pool Heater Pool Convection System Three U S Patents 5 014 770 5 452 710 5 746 653 SolarAttic Model PCS3...

Page 2: ...This page intentionally left blank...

Page 3: ...m 6 7 Basic Plumbing Diagram 8 Power The PCS3 9 Internal Wiring Diagram 10 Float Wiring Diagram 11 Goldline GL235 Solar Control 12 Goldline GL235 Circuit Board 13 Automation Wiring Diagram 14 Goldline...

Page 4: ...tion strikes the roof and reaches the attic through a process called conduction The SolarAttic pool heater is physically located inside the attic and then transfers this solar radiation from the attic...

Page 5: ...wered from the actual attic peak heat transfer performance can be dramatically reduced 7 The pool water sensor can be influenced by the sun and rain Shelter the pool water sensor as much as is possibl...

Page 6: ...VERED BY THE MANUFACTURERS WARRANTY ASSEMBLE THE VALVES AND PIPES BEFORE ACTUAL WELDING TO MAKE SURE THE JOINTS FIT PROPERLY THIS INSURES YOUR PARTS ARE READY FOR PERMANENT CEMENTING PLUMBING CAUTION...

Page 7: ...BLE AND DOES NOT SMELL OF CHLORINE YOU HAVE THE RIGHT POOL CHEMISTRY CHECK WITH YOUR LOCAL POOL CHEMICAL DEALER IF YOUR POOL DOES NOT HAVE THESE ATTRIBUTES BUILDING CODE CAUTION INSTALL ALL EQUIPMENT...

Page 8: ...mating pvc female fittings to the copper pipe threads we recommend using silicone sealant and allowing the joints to properly cure for 24 hours before placing them into use Do not use teflon tape Loca...

Page 9: ...ort systems located far away from the attic can be relocated closer by extending the pool s support piping Extremely long pipe runs may require added horsepower from the pool s pump If your pump is in...

Page 10: ...I I I IN N N N R R R RE E E ET T T TU U U UR R R RN N N N L L L LI I I IN N N NE E E ES S S S PUMP S S S ST T T TR R R RA A A AI I I IN N N NE E E ER R R R I I I IN N N NT T T TA A A AK K K KE E E E P...

Page 11: ...Note Place the attic sensor above the PCS3 out of the air flow and at the apex or peak of the attic The discharge air of the PCS3 can cool the temperature sensor down causing erratic cycling on off of...

Page 12: ...on this speed If the blower just hums this motor starting capacitor will have to be replaced Turn the power off remove the electrical cover panel and replace the capacitor Ensure the new capacitor is...

Page 13: ...pret the open circuit as a cold attic and shut down the PCS3 An open float also results in a flashing check sensor red light on the Goldline GL235 solar control The PCS3 must operate in the AUTO mode...

Page 14: ...Goldline GL235 Solar Control 12...

Page 15: ...Goldline GL235 Circuit Board 13...

Page 16: ...2 No connection 3 115 vac Hot Side from timer black 4 115 vac Neutral from timer white 5 115 vac Hot Side from timer to GL 235 Relay black 6 115 vac Hot Side from Relay to SolarAtttic Outlet black Ne...

Page 17: ...15 Goldline Wiring Option 220 VAC...

Page 18: ...llations maximum heat extraction is limited by human intervention or semi automated devices like switches or timers However heat extraction can be easily maximized and automated by way of an optional...

Page 19: ...need to be changed Note This is also a very rare occurrence 6 Some evidence of a small amount of condensate will be present in the form of a water stain in the interior of the PCS3 base pan This is n...

Page 20: ...amount of residual water that is trapped within the bottom of the coil The non toxic RV antifreeze available at local hardware stores dilutes any residual water and prevents winter freeze damage Winte...

Page 21: ...ssibility of a period of one or more days when temperatures below freezing are occurring or being forecasted by prevailing weather OR you may be simply late in getting around to winterizing your pool...

Page 22: ...e entire assembly can also be completely dismantled using only a few tools a a portable drill or electric drill b a 5 16 hex head bit c a No 2 phillips screwdriver or drill bit and d two 1 2 socket or...

Page 23: ...e 6 Internal PCS3 blower motor thermal cutoff Wait 15 minutes for it to cool off then retry 7 Defective PCS3 power cord or plug 8 Defective Motor starting capacitor 9 Defective Motor 10 Defective Sola...

Page 24: ...rnal limit switch needs adjusting 2 Internal cam needs adjusting 3 Internal mechanical stop needs adjusting 4 Defective valve operator Replace TEST Reverse the VOR Switch Turn it from ON1 to the ON2 p...

Page 25: ...disconnected sensor wires 1 Poor solar weather No Sunshine 2 Pump Timer out of sync with solar energy collection time causing pool to cool too much time 3 Water flow valves to PCS3 are shut off or re...

Page 26: ...waterfall It masks performance of PCS3 or offsets the heat gains of the PCS3 Waterfalls on a pool can have a dramatic cooling effect on pool temperature 1 Pool water temperature sensor exposed to coo...

Page 27: ...size of the filter pump 3 Slave the filter pump to the GL235 power relay us ing an external relay as shown online and also use a minimum runtime timer This will ensure that only the minimum filtration...

Page 28: ...nd the products they manufacture receive regular ETL safety reviews during each year to maintain product safety certifications When you buy the PCS3 you can have full confidence that the SolarAttic pr...

Page 29: ...Single Speed Noise 62 db A weighted 67 db C weighted 10 feet Plumbing Connections 2 Male Pipe Threads Pressure Drop 4 6 PSI typical Air Flow Rate 2600 SCFM Water Flow Rate Range 15 65 GPM Optimal Wate...

Page 30: ...They are waffled in appear ance and not straight Fin bending that has been combed with a fin tool does not affect performance and is not considered a manufacturing defect Our obligation under this war...

Page 31: ...This page intentionally left blank...

Page 32: ...5 West Veum Appleton Minnesota 55311 www solarattic com 2003 2016 All Rights Reserved Version 1 5 ETL Contents subject to change Original Appleton Minnesota Manufacturing Crew in 2003 Made In The U S...