24VDC PRO-Verter 7000-120 AGS Operator Manual
Continued on next page
SETUP Button Menus continued
04H Gen Exercise
Off/On
Set Gen Run Temp
Start = OFF
Set Gen Run Temp
Time =0.5
continued
SETUP
04E Gen Run Temp
Ext Input
Status
04 AGS Setup
Set Gen Run Temp
Start = Ext Input
Set Gen Run Temp
Time =0.5-25.5 Hrs
Default = OFF
Set Gen Run Temp
Start = 65F-95F
Set
Max Gen Run
Time = 12.0 Hrs
04F Max Gen Run
Time = OFF
Set
Max Gen Run
Time = 0.1-25.5 Hrs
Default = 12.0 Hrs;
Range: 0.1-25.5 Hrs
Set
Quiet Time
OFF
Set Start Quiet
Hour = 1:00
Set Start Quiet
Minute = 00:45P
Set Start Quiet
AM-PM = 0:00P
04G Quiet Time
Press Select
Set
Quiet Time
ON
Set Start Quiet
Hour =1:00-12:00PM
Set Start Quiet
Minute = 0:00P
Set Start Quiet
AM-PM = 0:00A
Default = OFF
Set Stop Quiet
Hour = 1:00P
Set Stop Quiet
Minute = 00:45P
Set Stop Quiet
AM-PM = 00:00P
Set Stop Quiet
Hour= 12:00P
Set Stop Quiet
Minute = 00:00A
Set Stop Quiet
AM-PM = 00:00A
Set Quiet Time
Topoff = 30-120Min
Set Quiet Time
Topoff = Off
Set
Gen Exercise
Days=2
Set Exercise Run
Hour=8:00
Set Exercise Run
Minute=#:00-#:59
Set Exercise Run
AM-PM= 8:00P
Set
Gen Exercise
Days=1-255 Days
Set Exercise Run
Hour=1:00-12:00A
Set Exercise Run
Minute= 8:00
Set Exercise Run
AM-PM= 8:00A
Set Exercise Run
Time= 1-25.5 Hrs
Set Exercise Run
Time= 2.0 Hrs
04I Gen Warm-up
Time = 15 Sec
Gen Warm-up
Time = 15 Sec
Gen Warm-up
Time =0-127 Sec/Min
Default = 60 Seconds
OFF = 0 Seconds
Range: 0-127 seconds; 0-127 minutes
04J Gen Cool Down
Time =
60 Sec
Gen Cool Down
Time = 60 Sec
Gen Cool Down
Time =0-127 Sec/Min
Default = 60 Seconds
OFF = 0 Seconds
Range: 0-127 seconds; 0-127 minutes
SETUP: 04 AGS Setup