Bunsen Air - Installer Manual
8 |
P a g e
5
Bunsen Air Installation
S
electing the Controller installation right location:
As part of any installation, a survey of the property should be carried out. It is important to locate the Controller as
close to the cylinder as possible, and keeping the distance to the panels as short as possible.
Check with the Warranty conditions for factors to avoid when locating the Controller.
For installation, the Bunsen Air should be supplied with
the following parts,
Component
Qty
Bunsen Air
1
Rubber Gasket
4
Mounting Bracket
2
********Back Board
– not provided but
recommended********
Choosing the Bunsen Air installation location
Do not install the Bunsen Air in outdoor location as it
is designed for indoor installation only. (It is not
waterproof.)
Avoid locations where the unit is exposed to direct
sunlight or other sources of heat.
Select a location where easy wiring access to the
power souce is available.
Avoid locations where combustible gases may leak,
be produced, flow, or accumulate.
Avoid areas with corrosive gases and strong
electromagnetic waves.
Select a location that can bear the weight and
vibration of the unit.
Select a location where
the water pipe-run
distance between Bunsen Air and water cylinder
is as short as possible. The pipe-run distance is
max. 5 meters with a max. vertical gain of 2
meters, amd a max. horizontal distance of 3
meters.
ALWAYS: Keep pipe runs to a minmum. The
shorter the pipe-run the better the performance.
Must be installed in a level, horizontal position and
sited on a solid, external wall where possible.
Horizontal Distance between Controller and Cylinder:
Vertical Distance between Controller and Cylinder:
Horizontal and Vertical
Max. 5 meters
Bunsen Air
Cylinder
Vertical
Max. 2 meters
Cylinder
Bunsen Air
Bunsen Air
Cylinder