Temperature Probe Installation
THE
TEMPERATURE
PROBE
MUST
BE
INSTERTED INTO THE PROBE POCKET, OR DRY
POCKET OF THE CYLINDER.
The temperature probe is used to monitor the
temperature of the cylinder. The probe cable can
extend to the length of 10 meters.
If there is no pocket available to use, it shall be
attached 1/3
rd
position from the bottom of cylinder.
To ensure a reliable and solid contact between the
probe and cylinder side, thermal paste should be
used.
Note
To make sure the reliable and solid contact
between the probe and cylinder side, the
thermal paste shall be used.
sensor pocket
sensor pocket
sensor pocket
sensor pocket
Steps
1. Locate the position of sensor pocket on the
cylinder.
2. Remove the sensor pocket cover.
3. Pass the temperature probe through the cover.
4. Push the temperature probe as far as possible into
the cylinder pocket, and then tighten the cover.
7
Bunsen Panel Installation
Position between Bunsen Panel and Bunsen Controller
Choosing the Bunsen Panel location
Select a location where
the standard pipe-run
distance between Bunsen Air and Bunsen panel
is 10 meters,
and minimum is not less than 5
meters.
If the pipe-run height length is more than
4 meters
, please install “Return Bend” on the
pipe.
ALWAYS: The shorter the pipe-run distance, the
better the performance.
Standard pipe
–run
distance: 10 meters,
Min. 5 meters
Height-length: more
than 4 meters with