Operating Instructions and Installation Guide
Wall Mounted Split System
Page 7
1.1
SolAir World SWWR-72GW
Rated Cooling Capacity (Watts)
7200
Rated Heating Capacity (Watts)
7900
Rated Power Input (Volts/Hertz)
220V/50Hz/60Hz
Rated Cooling Power Input (Watts)
1540 - 1760
Rated Cooling Input Current (Amperes)
6.43 - 7.34
Maximum Cooling Power Input (Watts)
2375
Maximum Cooling Input Current (Amperes)
10.8
Rated Heating Power Input (Watts)
1540 - 1780
Rated Heating Input Current (Amperes)
6.43 - 7.45
Maximum Heating Power Input (Watts)
2440
Maximum Heating Input Current (Amperes)
10.8
Auxiliary Electric Heating Rated Power Input (Watts)
350
Auxiliary Electric Heating Rated Input Current (Amperes)
1.60
Inhaling Maximum Working Pressure (Megapascals)
1.15
Exhausting Maximum Working Pressure (Megapascals)
4.1
Type of Refrigerant
R - 410A
Standard amount of Refrigerant (grams)
1850
Air Circulation of Outdoor Unit (Metres cubed/hour)
1050
Waterproof Grade
1PX4
Net Weight Outdoor Unit (Kilograms)
55
Net Weight Indoor Unit (Kilograms)
21
Dimensions Outdoor Unit (Millimetres–Length/Width/Height)
940/300/755
Dimensions Indoor Unit (Millimetres – Length/Width/Height)
985/325/230
Noise Level Outdoor Unit (Decibels)
<44
Noise Level Indoor Unit (Decibels)
<38
_______________________
Parameters in this table are measured in the rated working state of an outdoor
temperature of 35°C dry bulb 24°C wet bulb and an indoor temperature of
27°C dry bulb/19°C wet bulb.
Working states at varying temperatures may change