Operating Instructions and Installation Guide
Wall Mounted Split System
_______________________
Page 14
2.0 Trouble Shooting
Non Failure Conditions
When the SolAir World Air Conditioning System is turned on or off sometimes you will hear a sizzling
malfunction.
The SolAir World Air Conditioning System cannot instantly restart after it is stopped, even though it is
switch on. The compressor will take 3 minutes before it resumes operation if it has been switched off
then back on.
Occasionally stale/uncomfortable air is emitted by the system, if this happens follow the procedure in
If while heating, the indoor and outdoor units stop simultaneously but the compressor is still running the
SolAir World Air Conditioning System is in defrosting mode. This is not a malfunction, the heating will
Failure Display Indicators
While heating, the outdoor unit may generate condensation. This is a result of the defrosting process
and thawing, it is not a malfunction.
Model No.’s SWWR-26GW and SWWR-35GW
Failure Type
Display Status
Indoor Temperature Sensor Failure
E1
Indoor Coil Transmitter Failure
E2
System Failure
E4
If any of these failure display indicator occur please refer to E4 Trouble Shooting then contact
either the tradesman who installed the system or the distributor of the product.
Model No.’s SWWR-60GW and SWWR-72GW Failure Type
Failure Type
Display Status
Indoor Temperature Sensor Failure
Indicator light shines 1 time for 8 seconds
Indoor Coil Transmitter Failure
Indicator light shines 2 times for 8 seconds
System Failure
Indicator light shines 4 times for 8 seconds
If any of these failure display indicator occur please refer to E4 Trouble Shooting then contact
either the tradesman who installed the system or the distributor of the product.