![Solair World SWWR-26GW Installation And Operation Instruction Manual Download Page 30](http://html1.mh-extra.com/html/solair-world/swwr-26gw/swwr-26gw_installation-and-operation-instruction-manual_1313286030.webp)
Operating Instructions and Installation Guide
Wall Mounted Split System
_______________________
Page 28
2.2 Indoor Unit Installation
Check
Connecting the Piping
CAUTION
Indoor
work again.
1. Prepare the indoor unit's piping and drain hose for
installation through the wall.
2. Remove the plastic tubing retainer (see the figure
adjacent) and pull the tubing and drain hose away from
chassis..
1. Route the indoor tubing and the drain hose in the
direction of right rear.
2. Insert the connecting cable into the indoor unit from the
outdoor unit through the piping hole
Do not connect the cable to the indoor unit.
Make a small loop with the cable for easy connection
later
3. Tape the tubing, drain hose, and the connecting cable.
Be sure that the drain hose is located at the lowest
side of the bundle. Locating at the upper side can
If the drain hose is routed inside the room, insulate the
hose with an insulation material* so that dripping from
"sweating"(condensation) will not damage furniture or
* Foamed polyethylene or equivalent is recommended
For right rear piping