HP T2 PANEL
SERVICE MANUAL
5.2. Service Autotest Steps
STEPS
Control
Minimum Step
Duration*
Error
code
Led Indication
Possible Errors
The Routine to
Enter Servis
Autotest
Set program knob at position 3. Push SW5
button.
Keeping SW5 button pushed, turn program
knob to position 1. After 3 sec, SAU is shown
in display.
Then press Start/Pause button. Machine
enters to service autotest.
For T2: When machine enters service
autotest, SAU becomes fix on for 2 sec and all
warning leds make fast blink for 2 sec and
then becomes fix off
For T2: Machine shows the last error saved
by machine. If there is no error, "- - -"
visualise on the display
When knob positioned to program 2, control
steps starts.
5 sec
-
Step 2
(Knob Position
2)
Dryer check Aquaswitch, if aquaswitch ON go
to next step (pump activation), if aquaswitch
OFF give water tank full error
10sec
E03
-
*Aquaswitch connector is
taken out
*Aquaswitch connector is
short circuit
*Styrofoam is borken or not
Summary of Contents for HP T2
Page 1: ...TUMBLE DRYER SERVICE MANUAL HP T2 PANEL A Inverter...
Page 20: ...HP T2 PANEL SERVICE MANUAL 6 6 Side Panel 1 Remove 10 screws on side panels...
Page 24: ...HP T2 PANEL SERVICE MANUAL 6 9 Rear Cover 1 Remove all screws shown in the photo...
Page 39: ...HP T2 PANEL SERVICE MANUAL 6 21 Plinth 1 Open the plinth as shown in the photo...
Page 41: ...HP T2 PANEL SERVICE MANUAL 6 23 Plinth Cover 1 Remove 2 plinth pin on Plinth cover...
Page 43: ...HP T2 PANEL SERVICE MANUAL 6 26 Drum Bearing Wheel 1 Remove wheels as shown in the photo...
Page 53: ...HP T2 PANEL SERVICE MANUAL 7 1 1 Motor Measurements 2 1 2 3 1 3 3 1 2...
Page 55: ...HP T2 PANEL SERVICE MANUAL 7 2 1 Pump Measurements 2 1 1...
Page 59: ...HP T2 PANEL SERVICE MANUAL 7 5 1 Compressor Measurements 2 1 3 c r s r c s c s r...
Page 69: ...HP T2 PANEL SERVICE MANUAL...