SOGEDIS HP T2 Service Manual Download Page 69

 

HP T2 PANEL  

 

SERVICE MANUAL 

 

 
 

 

Summary of Contents for HP T2

Page 1: ...TUMBLE DRYER SERVICE MANUAL HP T2 PANEL A Inverter...

Page 2: ...UTOTEST 8 5 1 Failure Modes and Warning Leds 8 5 2 Service Autotest Steps 9 6 DISASSEMBLY 12 6 1 Top Plate 12 6 2 Control Panel 13 6 3 Inverter Card Box 16 6 3 Inverter Card Box 17 6 4 Electronic Card...

Page 3: ...ONENT SPECIFICATIONS AND MEASUREMENTS 52 7 1 Motor 52 7 1 1 Motor Measurements 53 7 2 Pump 54 7 2 1 Pump Measurements 55 7 3 Electronic Card 56 7 4 Door Compressor NTC Sensor 56 7 4 1 Door NTC Sensor...

Page 4: ...hich called by condenser The humidity of the laundry is taken and reaches the cold side of the coil which called by evaporator via filter With a compressor refrigerant is passed through inside of the...

Page 5: ...be appropriate to program 6 Use this product only for laundry with a label that indicates it is suitable for drying 7 Children should not play with appliance 8 This product contains environmental fri...

Page 6: ...el Display Symbols 4 2 Program List KNOB POSITION PROGRAM 1 Cotton Extra Dry 2 Cotton Cupboard Dry 3 Cotton Iron Dry 4 Synthetics Cupboard Dry 5 Synthetics Iron Dry 6 Delicate 7 Time Drying 8 Baby Car...

Page 7: ...cottons programme Refresh Time drying option is selected from 10 minutes to 150 minutes without providing hot air refresh is done and bad odors can be eliminated 4 3 Children s Safety There is a chil...

Page 8: ...ompleted filter led makes slow blink to indicate that service can pass the next step For error codes leds must make fast blink ERROR CODE REASON E00 Touch UI board doesn t receive communication from m...

Page 9: ...e autotest For T2 When machine enters service autotest SAU becomes fix on for 2 sec and all warning leds make fast blink for 2 sec and then becomes fix off For T2 Machine shows the last error saved by...

Page 10: ...ving to CW If not Motor connector is taken out Motor might be locked Motor belt might be dislocated Step 5 Knob Position 5 Motor CW Tumble CCW Motor stops 10 sec Service must check whether tumble is m...

Page 11: ...ivity sensor when door is opened and motor is off 5 sec E01 Service puts his hand on the humidity sensor plates and software checks sensor data If sensor data 0 humidity sensor connector is taken out...

Page 12: ...HP T2 PANEL SERVICE MANUAL 6 DISASSEMBLY 6 1 Top Plate 1 Remove two screws that fix the top plate at the back 2 Remove by pulling the top plate to yourself...

Page 13: ...HP T2 PANEL SERVICE MANUAL 6 2 Control Panel 1 Remove 2 screws from the top 2 After the water tank removed the plastic screw in the center of the control panel should be removed...

Page 14: ...he control panel the control panel is removed as shown in the photo from the upper support bracket 2 The cables on the control panel are carefully removed from the cable paths 3 All sockets which is c...

Page 15: ...HP T2 PANEL SERVICE MANUAL 6 2 Control Panel 4 Remove the PCB box by pressing clips which provide fixing to panel So PCB box will be separated from control panel...

Page 16: ...ter Card Box 1 All sockets which is connected with inverter card box must be removed carefully as shown in the photo 2 After removing the sockets on the card box the inverter card box is removed as sh...

Page 17: ...ICE MANUAL 6 3 Inverter Card Box 1 For opening the Inverter card box press the clips 6 units Care should be taken not to break the clips here 2 The inverter card inside is removed from the nails as sh...

Page 18: ...Electronic Card 3 For opening the PCB box press the clips 6 units Care should be taken not to break the clips here 4 The electronic card inside is removed from the nails Remove the electronic card fro...

Page 19: ...HP T2 PANEL SERVICE MANUAL 6 5 UI Card 1 Remove screw on UI card as shown in photo 2 Display card on control panel is disassembled as shown in photo...

Page 20: ...HP T2 PANEL SERVICE MANUAL 6 6 Side Panel 1 Remove 10 screws on side panels...

Page 21: ...HP T2 PANEL SERVICE MANUAL 6 6 Side Panel 2 Remove 2 screws from front 3 It should not be forgotten to take bottom screw 2 screws 4 Remove the side plate which is pulled out screws by pushing up...

Page 22: ...HP T2 PANEL SERVICE MANUAL 6 7 Supply Cable 1 Remove the supply cable brown and blue cable socket 2 Remove the terminals with tool as shown in the photo 3 Remove supply cord by pushing up 3 2 1...

Page 23: ...HP T2 PANEL SERVICE MANUAL 6 8 Emi Filter 1 Remove EMI filter sockets 2 Remove the terminals with tool as shown in the photo 3 Remove the EMI filter which is fixed with 2 screws to the rear panel...

Page 24: ...HP T2 PANEL SERVICE MANUAL 6 9 Rear Cover 1 Remove all screws shown in the photo...

Page 25: ...1 Remove the screw on pump cover 2 After opening the pump holder plastic cover Remove 2 hoses that is connected with pump 3 Remove aqua switch and pump socket 4 Remove the pump holder plastic from ba...

Page 26: ...HP T2 PANEL SERVICE MANUAL 6 10 Pump 5 Push the pump from plastic 6 There is a float in the pump housing as shown in the photo...

Page 27: ...HP T2 PANEL SERVICE MANUAL 6 11 Process Fan 1 Hold the fan as shown in the photo 2 First remove washer and nut then remove the process fan...

Page 28: ...HP T2 PANEL SERVICE MANUAL 6 12 Rear Panel 1 Remove segment on rear panel 2 Remove 8 screws from panel...

Page 29: ...HP T2 PANEL SERVICE MANUAL 6 12 Rear Panel 1 Remove hoses from rear panel 2 Remove the rear panel by pulling to yourself...

Page 30: ...HP T2 PANEL SERVICE MANUAL 6 13 Rear Isolation Group 1 For disassembling the rear Isolation group on rear panel screws are shown in the photo should be removed...

Page 31: ...HP T2 PANEL SERVICE MANUAL 6 14 Rear Bearing Group 1 For disassembling the rear bearing group on rear panel screws are shown in the photo should be removed...

Page 32: ...HP T2 PANEL SERVICE MANUAL 6 15 Water Tank Housing 1 Remove 2 hoses from water tank housing 2 Remove the water tank housing clips 3 The water tank housing is removed as in the photo...

Page 33: ...UAL 6 16 Drum 1 Motor should be moved up to prevent to press spring So belt will be released as shown in the photo 2 Remove the belt on the drum 3 Pull up the drum to separate with basement plastic Th...

Page 34: ...ove 4 screws from motor fixing plastic 2 Take the motor from basement plastic as shown in the photo 3 Remove sockets from motor PS before removing the motor process fan should be removed 4 You can app...

Page 35: ...HP T2 PANEL SERVICE MANUAL 6 18 Capacitors 1 Remove capacitor sockets 2 Remove the screw on bottom of capacitor then disassemble the capacitor 3 The capacitor is removed by turning...

Page 36: ...HP T2 PANEL SERVICE MANUAL 6 19 Belt 1 After you should remove drum and motor than change the belt...

Page 37: ...HP T2 PANEL SERVICE MANUAL 6 20 Humidity Sensor 1 Remove 5 screws from humidity sensor plastic 2 Remove the humidity sensor cable as shown in photo...

Page 38: ...HP T2 PANEL SERVICE MANUAL 6 21 Door latch 1 Remove door latch screw from front panel 2 Separate the door latch socket from door latch as shown in the photo...

Page 39: ...HP T2 PANEL SERVICE MANUAL 6 21 Plinth 1 Open the plinth as shown in the photo...

Page 40: ...RVICE MANUAL 6 22 Cooling Fan 1 Remove screws on cooling fan fixing plastic 2 Remove the cooling fan fixing plastic as shown in the photo 3 Disassemble the cooling fan by removing the fan screws and f...

Page 41: ...HP T2 PANEL SERVICE MANUAL 6 23 Plinth Cover 1 Remove 2 plinth pin on Plinth cover...

Page 42: ...HP T2 PANEL SERVICE MANUAL 6 24 Door 1 Remove 2 screws that fix the door 2 Pull the door by lifting up...

Page 43: ...HP T2 PANEL SERVICE MANUAL 6 26 Drum Bearing Wheel 1 Remove wheels as shown in the photo...

Page 44: ...HP T2 PANEL SERVICE MANUAL 6 27 Drumlight 1 Remove Drumlight group from Front Shield 2 Remove the drum light socket 3 Remove the drum light card...

Page 45: ...HP T2 PANEL SERVICE MANUAL 6 27 Front Panel 1 Remove 16 screws on the front panel 2 While removing the front panel the cable of the door latch must also be removed...

Page 46: ...HP T2 PANEL SERVICE MANUAL 6 29 Door NTC 1 Remove the socket from NTC sensor on the basement plastic 2 Remove the NTC from basement plastic by hand or tool...

Page 47: ...ERVICE MANUAL 6 30 Side Bracket 1 Remove cable holder plastic clips shown in the photo For right side bracket 2 Remove screw from bracket which is fixing side bracket and top bracket Rear panel was re...

Page 48: ...HP T2 PANEL SERVICE MANUAL 6 31 Front Shield 1 Remove 2 screws in the bottom 2 Open clips on the left side 3 The front shield should be lifted as shown in the photo...

Page 49: ...he slot at the front shield 2 Before Sticky paper is opened front isolation foam should be placed to slot on front shield Front isolation foam mark should be on left bottom of front shield 3 Stick the...

Page 50: ...HP T2 PANEL SERVICE MANUAL 6 33 Cable Group 1 Open the cable holder plastic clips on side bracket 2 Remove cable holder plastic fixing clips as shown in the photo...

Page 51: ...T2 PANEL SERVICE MANUAL 6 33 Cable Group 1 Humidity Sensor Cable 4 Compressor NTS Socket 2 Door Latch Socket Cable 5 Compressor Ground Cable 3 Cable Group of Front Shield 6 Compressor Socket 1 2 3 4 5...

Page 52: ...d drum Drum speed 51 2 Component Test Check whether the motor cable is connected to the motor connector Check the connection of the capacitor cables Measure the resistance values and check the capacit...

Page 53: ...HP T2 PANEL SERVICE MANUAL 7 1 1 Motor Measurements 2 1 2 3 1 3 3 1 2...

Page 54: ...m Voltage 220 240 Volt Frequency 50 Hz Input Power 13W max Component Test Check the connection of the pump connector Check the pump resistances Check whether pump is working by feeding externally If t...

Page 55: ...HP T2 PANEL SERVICE MANUAL 7 2 1 Pump Measurements 2 1 1...

Page 56: ...ts sockets are inserted 7 4 Door Compressor NTC Sensor Two NTC sensors are used The NTC resistance decreases when the temperature rises Technical Features Door NTC Resistance 12 k Measured from IDC co...

Page 57: ...he photo on the right the terminal on the compressor are shown to be measured by multiple counters It is driven with relay via the electronic card to give energy and relay drive the compressor only on...

Page 58: ...eck the connection of the capacitor cables Measure the resistance values and check the capacitor values Check whether it is working by connecting via the terminals S R and C connection If it is workin...

Page 59: ...HP T2 PANEL SERVICE MANUAL 7 5 1 Compressor Measurements 2 1 3 c r s r c s c s r...

Page 60: ...It s designed to be opened from inside in case of children are in the drum Component Test When the door is closed check whether there is electrical transmission from IDC connected to electronic card...

Page 61: ...res the amount of dryness of the laundry in the drum Component Test Each humidity sensor plate is checked whether there is electrical transmission from IDC connected to electronic card Check the conne...

Page 62: ...n the compressor are shown to be measured by multiple counters It is driven with triac via the electronic card to give energy Technical Features Type single phase AC fan Power 28 W Main windings 600 7...

Page 63: ...ANEL SERVICE MANUAL 7 8 1 Cooling Fan Measurements 7 9 Drumlight Drumlight lights inside of the drum Component Test Check whether there is electrical transmission from IDC connected to electronic card...

Page 64: ...Hz Change The Main Board MACHINE IS NOTWORKING Is Electricity Reaching To Main Board YES YES Change the cable tree NO NO Machine has not a failure Is The Supply Cord Plugged Into The EMI Filter NO Ma...

Page 65: ...latch switch correct YES YES Fix the position of the switch NO NO YES Close Repair the door Is the door latch socket connection correct NO Make Electrical Connection YES Check the door latch with mul...

Page 66: ...correct Is drum rotating CW Change compressor NTC Change the compressor Check the drum is not rotating alg NO YES YES YES YES NO NO NO NO Is machine power correct YES NO Check the compressor gas YES I...

Page 67: ...orrectly Change The Motor Is Right and Left Wheel Rotating Check If Rear Isolation Group Is Stable Check If Front Isolation Group Is Stable Is Bearing Group Spherical Bearing stable and Solid Is Drum...

Page 68: ...correct NO Check the compressor gas YES Change the cable tree User should be informed about the machine YES NO Is connection of compressor connector correct Are the measured resistance values through...

Page 69: ...HP T2 PANEL SERVICE MANUAL...