![SOGEDIS HP T2 Service Manual Download Page 58](http://html1.mh-extra.com/html/sogedis/hp-t2/hp-t2_service-manual_1312542058.webp)
HP T2 PANEL
SERVICE MANUAL
Aux windings: 8.75±7% (25 °C temp.)
Motor speed : 2928 rpm (Unloaded)
Gas Type: R290
Capacitor value : 20 µF ± %5
Compressor Capacity: 6.8 cm³/rev
Component Test
Check whether the compressor cable is connected to the compressor terminal.
Check the connection of the capacitor cables
Measure the resistance values and check the capacitor values
Check whether it is working by connecting via the terminals S,R and C connection
If it is working, start the machine and check the drum temperature.
The terminals S and R of the motor should be connected with capacitor.
Resistance measurement of main winding: Terminal C-R is measured.
Resistance measurement of aux winding: Terminal C-S is measured.
Summary of Contents for HP T2
Page 1: ...TUMBLE DRYER SERVICE MANUAL HP T2 PANEL A Inverter...
Page 20: ...HP T2 PANEL SERVICE MANUAL 6 6 Side Panel 1 Remove 10 screws on side panels...
Page 24: ...HP T2 PANEL SERVICE MANUAL 6 9 Rear Cover 1 Remove all screws shown in the photo...
Page 39: ...HP T2 PANEL SERVICE MANUAL 6 21 Plinth 1 Open the plinth as shown in the photo...
Page 41: ...HP T2 PANEL SERVICE MANUAL 6 23 Plinth Cover 1 Remove 2 plinth pin on Plinth cover...
Page 43: ...HP T2 PANEL SERVICE MANUAL 6 26 Drum Bearing Wheel 1 Remove wheels as shown in the photo...
Page 53: ...HP T2 PANEL SERVICE MANUAL 7 1 1 Motor Measurements 2 1 2 3 1 3 3 1 2...
Page 55: ...HP T2 PANEL SERVICE MANUAL 7 2 1 Pump Measurements 2 1 1...
Page 59: ...HP T2 PANEL SERVICE MANUAL 7 5 1 Compressor Measurements 2 1 3 c r s r c s c s r...
Page 69: ...HP T2 PANEL SERVICE MANUAL...