OPERATING CONDITIONS & REQUIREMENTS
Page 5
EN - English
•
OPERATING PRESSURE MAX: 6,0 bar / 87 psi
−
check water pressure regularly.
−
take into account that night time water pressure may be considerably
higher than day time water pressure.
−
install a pressure reducer ahead of the appliance
if necessary.
•
OPERATING TEMPERATURE MIN-MAX: 5-38 °C / 41-100 °F
−
do not install the appliance in an environment where high ambient
temperatures or freezing temperatures can occur.
−
the appliance cannot be exposed to outdoor elements, such as direct
sunlight or atmospheric precipitation.
•
ELECTRICAL CONNECTION:
−
the appliance only works on 24 VDC; always use it in
combination with the supplied transformer.
−
make sure to plug the transformer into a power outlet, which is
installed in a dry location, with the proper rating and over-
current protection.