190
6.14.6 Percent Control
The function "Percent Control" is used to meter weights / goods with tolerance control into a
container or to control quantities.
In order to start the percent control function, you must already have a reference weight assigned
to a percentage; the display then shows the unit %
Press the F5 Perc. Contr. key in the Control Function level 2.
Use the number keypad to enter the desired target value in percent; confirm with the F6 Save key.
Use the number keypad to enter the acceptable tolerance in percent; confirm with the F6 Save key.
If you wish to specify the plus and minus tolerances separately, you will need to set Program
Settings / Percent Weighing / Se/- Tolerance to On in setup mode.
The display starts the indicator light function with the special characters in the display view. A
prerequisite is that the factory default or indicator light function is enabled in the info field.
The appropriate indicator light color with special character is displayed to match the current status
of the scale to target value.
Control state
Indicator light color
Special character
Below tolerance limit
yellow
In tolerance
green
Exact target value reached
green
Above tolerance limit
red
You can also display the difference to the target weight in figures with + or - sign in the top left
corner of the secondary display. Enable the secondary display with the F3 Secondary Display key in
level 4 of the settings functions.
Displaying target value and tolerance
Press the Info key followed by the F3 Perc Contr key.
Record/print within or outside of tolerance
The release of a data record outside of a specified tolerance range can be prevented or accepted.
If a data record is released outside of the tolerance, it is marked with a special character. Release
or lock are set in setup mode under Program Settings / Percent Weighing / Record Outside of
Tolerance.