74
A
PPENDIX
D
E
NABLING OR
D
ISABLING
S
YMBOLOGIES
The Cordless Ring Scanner is pre-set to automatically detect and decode (auto-
discriminate) the most common bar code symbologies. To enable or disable
symbologies, simply use the SocketScan Symbology Selector.
Notes:
•
The length of some symbologies will change after Symbology Selector is used.
See Table 1.
•
With more symbologies enabled, the scanner must work harder to search through
all the possible combinations. This may make the decoding process slightly
longer.
•
The advanced symbology parameters listed in Table 2 can only be modified by
using the SocketScan Advanced Programming Guide or the SocketScan SDK.
Check the Socket Mobile website for updates.
Table 1. Default Symbologies
Symbology
Scanner
Default
Default
Length
Length after
Symbology Selector
UPC/EAN/JAN
UPC-A Enabled
N/A
N/A
UPC-E Enabled
N/A
N/A
UPC-E1 Disabled
N/A
N/A
EAN-8 Enabled
N/A
N/A
EAN-13 Enabled
N/A
N/A
Code 128 (USS-128 & UCC/EAN 128)
Enabled
Any Any
Code 39*
Code 39
Enabled
2 to 23
2 to 55
Trioptic Code 39
Enabled
2 to 23
2 to 55
Code 39 Full ASCII
Disabled
2 to 23
2 to 55
Code 93
Disabled
2 to 38
2 to 55
Interleaved 2 of 5*
Enabled
14 Only
2 to 55
Discrete 2 of 5*
Disabled
12 Only
2 to 55
Codabar
Disabled
5 to 55
2 to 55
MSI Plessey*
Disabled
1 to 30
2 to 55
RSS-14 (Standard, Limited, Expanded)
Disabled
N/A N/A
*Warning: Setting the length to “Any” may lead to inaccurate decodes of these symbologies.