9
© Trynex International 2012 (REV A) F50734
WARNING PROTECTION
•
I
f audible beeping occurs, read display to identify problem. If display reads “OL” (overload) or “OH” (overheat), shut the controller down and
carefully clear jammed auger. If display reads “E1” this means there is a dead short in the system. Do not use until problem is corrected. If
the display reads “E0” this means the motor is not getting any power. Check all connections. If the display reads “LB” the vehicle battery is
extrememly low (possibly caused by a poor or corroded connection) and could damage the system.
•
If there are any problems while operating the spreader, refer to Troubleshooting Guide.
AUTO-REVERSE “AR” FUNCTION
•
If your controller displays “OL” this could indicate a jammed auger.
•
To engage the Auto-Reverse “AR” Function:
Step 1: Shut the Main Power Switch OFF for 3 seconds.
Step 2: Turn the Main Power Switch ON. When the machine starts back up, the “AR” sequence will automatically start and the auger will
reverse for several rotations to clear the jam.
•
After a pause of several moments, the auger will automatically return to correct rotation. If the jam is still not cleared, the controller will again
display “OL.”
• You may repeat Steps 1 and 2 for a second and third time.
•
If after the third try the controller displays “OL,” you must extract the material that is causing the problem.
•
Follow all warning directions when clearing jams.
Operating the Spreader
(continued)
Model # SP-9500X