IQH3A IQ 3U Modular Enclosure
www.snellgroup.com
Operation
Issue 2 Rev 2
Page 66
©
2014 Snell Limited
THUMB_IP_PORT
Thumb IP Port value
NUMBER
Reports the IP Port number used for
Hyperion Thumbnail monitoring.
Ensure enabled if Hyperion monitoring
uses the auto discovery feature.
SNMP_NAME=
SNMP Name
Text
Reports the SNMP system name as
specified in the MIB2 sysName field on
the SNMP page.
LOCATION=
Location
Text
Reports the SNMP physical or logical
system location as specified in the
MIB2 sysLocation field on the SNMP
page.
SYSTEM_CONTACT=
System Contact
Text
Reports the SNMP system contact as
specified in the MIB2 sysContact field
on the SNMP page.
SYSTEM_DESCRIPTION=
System Description
Text
Reports a description of the gateway
type, for example IQH3UM4-S.
LOGGING_STATE=
Logging State
OK
WARN:No Logserver
WARN: Address Change
FAIL:Name Change
This log field indicates wehter logging
is functioning properly.
Note
: When Gateways are set to log,
there should only be one LogServer. It
is not recommended to log to more
than one LogServer. It is possible to
see more than one LogServer over
multiple network addresses, but again,
this is not recommended.
POWER_MAX=
Max Power Available
141W - Power for IQH3A
63W - IQH1A
165LU - IQH3B, (Load Units)
Maximum power according to
enclosure type.
POWER_USAGE=
Power Usage
OK:nnnW or OK:mmmLU
e.g. OK:74W / OK:72LU
WARN:nnnW or WARN:mmmLU
e.g. WARN:144W / WARN:167LU
Current power usage of all cards fitted.
This will indicate WARN if value
exceeds POWER_MAX
POWER_CHECK=
Power Detail Check
OK
WARN:REFER MANUAL
Reports if cards have a known power
rating, or not. If any card is not
recognized it will port WARN:REFER
MANUAL, else OK.
IP_BRIDGE_STATUS=
IP Bridge Status
OK:Active (Connected)
FAIL:Inactive (Disconnected)
INFO:Active (Connected)
INFO:Inactive (Disconnected)
When enabled, changes logging state
of log field IP_BRIDGE_STATUS to OK
or FAIL instead of INFO.
Field Name
Field Name Description
Valid Field Values
Usage Description