IQH3A IQ 3U Modular Enclosure
www.snellgroup.com
Operation
Issue 2 Rev 2
Page 63
©
2014 Snell Limited
LAN_PORT_n_LAST_CHANGE
Time from start since last Port Change
Number
DDD:HH:MM:SS
Time change when IP interface
parameters altered (ie IP subnet)
Uptime in specified format updated
every minute, NOTE: field value is zero
buffered 001:08:10:00 (is 1 day, 8
hours, 10 minutes, 0 seconds)
Derived from MIB-II ifLastChange
LAN_PORT_n_ERRORS
Total number errors
XXX in total
Summation of MIB-II values
ifInDifIifInUnknownPr
otos+ifOutDifOutErrors.
Updated periodically (60 sec interval)
LAN_PORT_n_TRAFFIC_IN
Traffic In / min
NNN.n Kbytes/sec
MIB-II ifInOctets. e.g.
“LAN_PORT_5_TRAFFIC_IN=12.3
KBytes/sec”
Format (“%0.1f”)
LAN_PORT_n_TRAFFIC_OUT
Traffic Out / min
NNN.n Kbytes/sec
MIB-II ifOutOctets. e.g.
“LAN_PORT_5_TRAFFIC_OUT=12.3
KBytes/sec”
Format (“%0.1f”)
IP_EVENT
Text
xxx.xxx.xxx.xxx CONNECT FROM
xxx.xxx.xxx.xxx DISCONNECT FROM
xxx.xxx.xxx.xxx BRIDGE CONNECT
TO
xxx.xxx.xxx.xxx BRIDGE CONNECT
FROM
Free text for miscellaneous IP event
messages such as
xxx.xxx.xxx.xxx CONNECT FROM.
Note IP address is not zero buffered.
This column is informational and not to
be used for defined error states
LAN_PORT_n_STATE
Ethernet connection state
Active
WARN: Inactive
Does the Ethernet have electrical
connectivity
UPTIME
Uptime in seconds
Number
DDD:HH:MM:SS
Uptime in specified format updated
every minute, NOTE: field value is zero
buffered 001:08:10:00 (is 1 day, 8
hours, 10 minutes, 0 seconds)
RESTARTED_AT
Last Restarted (UTC)
UTC Timestamp
UTC Time of last reboot, formatted as
per ISO8601 as above.
Field Name
Field Name Description
Valid Field Values
Usage Description