ARC130S SECTION
4
ARC130S 060801 Version 1 Issue 1
4.21
VITS
This allows you to control the blanking of the
vertical interval lines. Note that for 625/50
operation the lines are 7-22 and 320-335, and for
525/59.94 operation the lines are 10-20 (and line
21 if set up to L21 Capt, as above) and 272-282.
From the Home Screen, press ENT and scroll to
VITS. Press ENT and scroll to select the function
you require. Then press ENT again.
PassAll
passes all the VITS lines through the
ARC130S untouched. When selected and ENT is
pressed, the message “Done” appears.
BlankAll
blanks all the VITS lines. When selected
and ENT is pressed, the message “Done” appears.
Field 1
allows you to selectively pass/blank field 1
vertical interval lines. Similarly,
Field 2
allows you
to selectively pass/blank field 2 vertical interval
lines.
Setline: selects which vertical interval lines of the
appropriate field are to be blanked/passed.
State: turns on and off the blanking for the lines set
in Setline. Pressing ENT toggles the message
between “Pass” and “Blanked”.