ARC130S
SECTION 3
Installation
ARC130S 060801 Version 1 Issue 1
3.6
GPI
GPI functions are implemented as follows:
GPI Inputs
MADE IN ENGLAND
CONTROL
GPI IN
1
1
2
These are accessed via two 9-way D type
connectors labelled 1 and 2. Each connector has 4
inputs and connections are as below.
GPI = GPI input
GPI input 1
Pin 2
GPI 0 signal
Pin 6
GPI 0 return
Pin 3
GPI 1 signal
Pin 7
GPI 1 return
Pin 4
GPI 2 signal
Pin 8
GPI 2 return
Pin 5
GPI 3 signal
Pin 9
GPI 3 return
Pin 1
safety ground.
GPI input 2
Pin 2
GPI 4 signal
Pin 6
GPI 4 return
Pin 3
GPI 5 signal
Pin 7
GPI 5 return
Pin 4
GPI 6 signal
Pin 8
GPI 6 return
Pin 5
GPI 7 signal
Pin 9
GPI 7 return
Pin 1
ground.
GPI Outputs
GPI OUT
1
1
1
13
3
3
30
0
0
0S
S
S
S
S
S
S
Se
e
e
errrriiiia
a
a
allll N
N
N
No
o
o
o....
These are accessed via a 25-way D type connector
and connections are as follows:
GPO = GPI output
Pin 2
GPO 0 signal
Pin 14
GPO 0 return
Pin 3
GPO 1 signal
Pin 15
GPO 1 return
Pin 4
GPO 2 signal
Pin 16
GPO 2 return
Pin 5
GPO 3 signal
Pin 17
GPO 3 return
Pin 6
GPO 4 signal
Pin 18
GPO 4 return
Pin 7
GPO 5 signal
Pin 19
GPO 5 return
Pin 8
GPO 6 signal
Pin 20
GPO 6 return
Pin 9
GPO 7 signal
Pin 21
GPO 7 return
Pins 1,10,11,12,13,22,23,24,25 ground
The GPO output characteristics are as follows:
Operating Voltage Range
0 to ±60 V
(DC/AC peak)
Maximum Load current
1.0 A (AC/DC)
Maximum On-State
Resistance @ Tamb =+25°C
500 mOhm
Minimum Off-State
Resistance
@Tamb =+25°C,V=±48V
100 MOhm